LP-250-300-600 NITROX
23
- 80
6
7
9
8
THERMOSTAT
FACTORY
SET 40°C
MAX O
2
ALLOWED 40%
4
5
OIL FILTER
CHANGE EVERY
1500 HOURS
ENGLISH
Heater temperature plate.
The heater temperature thermostat is set to 40 °C. Do not alter or modify
the temperature.
Oxygen percentage adjustment plate.
Act on the adjuster knob to increase or decrease the Oxygen percentage
in the Nitrox mix.
Mixing pipe filter plate.
Change the intake filter every 250 hours (see chapter “7.10 Changing the
mixing pipe filter”).
Maximum Oxygen percentage plate.
The Oxygen percentage in the NITROX mix must not exceed 40%.
Oil filter plate.
Change the oil filter every 1500 hours (see chapter “7.6”).
Live electrical circuit danger warning.
ITALIANO
Targhetta temperatura riscaldatore.
Il termostato della temperatura del riscaldatore è tarato in sede a 40°C. Non
alterare o modificare la temperatura.
Targhetta regolazione percentuale di Ossigeno.
Agendo sul pomello di regolazione si aumenta o diminuisce la percentuale
di Ossigeno presente nella miscela Nitrox.
Targhetta filtro aspirazione tubo miscelatore.
Sostituire il filtro di aspirazione ogni 250 ore (vedi capitolo “7.10 Sostituzione
filtro di aspirazione tubo miscelatore”).
Targhetta massima percentuale di Ossigeno.
La percentuale di Ossigeno presente nella miscela NITROX non deve essere
superiore a 40%.
Targhetta filtro olio.
Sostituire il filtro olio ogni 1500 ore (vedi capitolo “7.6”).
Avvertenza di pericolo presenza tensione elettrica.