29
Р
у
сс
к
и
й
It
a
lia
n
o
E
n
g
lis
h
D
e
u
tc
h
F
ra
n
ça
is
-
At the end of each blast chilling/blast freezing cycle.
-
At 6-hour intervals during holding.
The purpose of the evaporator sensor is to produce the utmost efficiency and shorten defrosting times by
measuring the end-of-defrosting temperature.
6.8
MANUAL DEFROSTING
This mode should be used only when further defrosting is required in addition to that performed
automatically by the appliance.
Shortcut commands while in standby mode
Shortcut commands while in standby mode
Shortcut commands while in standby mode
Shortcut commands while in standby mode
Make sure the appliance is working (6.1
6.1
6.1
6.1).
Hold button
down for 5555 seconds
.
The led by the button comes on, and goes off when cycle ends.
The defrosting cycle stops automatically. How long it takes depends on how much frost there is on the
evaporator coil.
Once defrosting has finished, the appliance resumes normal operation.
7.0
TEMPERATURE-BASED BLAST CHILLING/BLAST FREEZING
7.1
TEMPERATURE-BASED SOFT BLAST CHILLING
The temperature-based soft
soft
soft
soft blast chilling cycle is controlled by the needle probe.
Shortcut comma
Shortcut comma
Shortcut comma
Shortcut commands while in standby mode
nds while in standby mode
nds while in standby mode
nds while in standby mode
1
Soft blast chilling
2
Start
Detailed commands sequence
Detailed commands sequence
Detailed commands sequence
Detailed commands sequence::::
1.
Make sure the appliance is in standby
standby
standby
standby mode (6.1
6.1
6.1
6.1).
2.
Insert the needle probe in the product to be chilled (10.0
10.0
10.0
10.0).
3.
Press button
to select the soft
soft
soft
soft blast chilling cycle....
•
The led button
comes on.
•
Display DY1
DY1
DY1
DY1 gives the setpoint of the air in the compartment (----2°C
2°C
2°C
2°C).
•
Display DY2
DY2
DY2
DY2 reads “---
---
---
---”.
4.
Press button
to start the soft
soft
soft
soft blast chilling cycle.
•
The led button
comes on.
•
The compressor only starts working 5555 seconds after key
is pressed (pump-down 6.4
6.4
6.4
6.4).
•
DY1
DY1
DY1
DY1 gives needle probe temperature, and DY2
DY2
DY2
DY2 the cycle time remaining, counting down from 90
90
90
90
minutes.
•
If you press button
while the cycle is running, you can view the time elapsed since it started.
5.
A buzzer sounds to advise that the blast chilling cycle has finished.
6.
At the end of the cycle, holding mode starts and continues indefinitely at a holding temperature of +3°C
+3°C
+3°C
+3°C.
•
The led button
flashes.
•
If you press button
during holding time, you can view the time of the cycle just completed to see
how long it took.
•
The holding stage must last only as long as strictly necessary.
7.
To exit holding mode, press button
.
•
The led button
goes off.
•
The compressor stops 5555 seconds after button
is pressed (pump-down 6.4
6.4
6.4
6.4).
Содержание W10T
Страница 2: ......
Страница 22: ...22 Italiano English Deutch Fran ais...
Страница 40: ...40 Italiano English Deutch Fran ais...
Страница 79: ...79 Italiano English Deutch Fran ais 3 0 3 1 3 2 3 3 3 4 50 430 3 5 3 6 10...
Страница 80: ...80 Italiano English Deutch Fran ais 4 0...
Страница 90: ...90 Italiano English Deutch Fran ais 58 30 mm 48 mm 384 8 mm RS485 1 1 1 2 3 4 5 6 1 2 3 11 0 1 2 100 C...
Страница 91: ...91 Italiano English Deutch Fran ais 1 1 12 0 E0 E0 E0 E0...
Страница 94: ...94 Italiano English Deutch Fran ais 14 0 14 1 14 2 1 4 4 2 2 3 4 5 1 2 14 3 1 2 3...
Страница 95: ......