20
Chapter 3: Settng up the Printer
A776II Two-Color Thermal/Impact Hybrid Printer: User Guide
A776 2UG0001 B 11/2016
Enable or disable receipt test mode
The receipt test mode verifies proper receipt printing. Receipt test is enabled and disabled by selecting the “Diagnostic
Modes” sub-menu of the configuration menu. See “Configuring the printer” on page 17 for instructions on how to enter
the configuration menu.
To exit the Receipt test mode:
1. Enter the configuration menu again. See
“Configuring the printer” on page 17
2. Disable the receipt test mode.
3. Exit the configuration menu.
4. The printer is online and can again communicate
normally with the host computer.
To run the Receipt test mode:
1. Enable the receipt test mode in the configuration
menu.
2. Exit the configuration menu.
3. Push the paper feed button. The receipt station
prints two code pages and cuts the receipt.
4. To repeat this test, push the paper feed button
again.
Enable or disable slip test mode
The slip test mode verifies proper printing on a slip. Slip test is enabled or disabled by selecting the “Diagnostic Modes”
sub-menu of the configuration menu. See “Configuring the printer” on page 17 for instructions on how to enter the
configuration menu.
To run the slip test mode:
1. Enable the slip test mode in the configuration menu.
2. Exit the configuration menu.
3. Insert a slip into the slip station.
4. Push the paper feed button. Two code pages will be
printed.
5. To repeat this test, preform steps 3 and 4 again.
To exit the slip test mode:
1. Enter the configuration menu again. See
“Configuring the printer” on page 17.
2. Disable the slip test mode.
3. Exit the configuration menu.
4. The printer is online and can again communicate
normally with the host computer.
Enable or disable Magnetic Ink Character Recognition (MICR) test mode
In the MICR test mode the MICR reads the characters on a check, but instead of transmitting the values to the software
it prints them out.
You can enable or disable MICR test is enabled or disabled by selecting the “Diagnostic Modes” sub-menu of the
configuration menu. See “Configuring the printer” on page 17 for instructions on how to enter the configuration
menu.
To run the MICR test mode:
1. Enable the MICR test mode through the
configuration menu. Then exit the configuration
menu.
2. Insert a check into the slip station. See “Verifying
and validating checks” on page 25.
3. After the printer detects the check, the platen closes
and the characters are read by the MICR check
reader. The decoded data is printed as characters on
receipt paper. The platen then opens, and the test is
re-started.
4. The printed characters should match the characters
on the check. If the MICR check reader misreads a
character, it will print a question mark (“?”). If the
reader can’t read any of the characters, “NO MICR
CHARACTERS” appears.
To exit the MICR test mode:
1. Enter the configuration menu again.
2. Disable the MICR test mode.
3. Exit the configuration menu.
4. The printer returns to normal mode and can again
communicate with the host computer.