Chapter 3: Settng up the Printer
A776 2UG0001 B 11/2016
A776II Two-Color Thermal/Impact Hybrid Printer: User Guide
15
Sample diagnostic menu and print test for a printer with a serial connection. Ethernet diagnostic printout not shown.
Ethernet parameters can not be changed in the configuration menu.
Paper type can be changed in the configuration menu.
Paper types and grades available:
Type 0 - Monochrome grades
Type 4 - Two-color grades
Type 5 - Two-color grades
See the Programming Guide for more information.
Test Printout
- Set Firmware Features - > 8 clicks
*** A776II - Diagnostics Form ***
Model number : A776-0000-0000
Serial number
: 0000000000
Loader Firmware
P/N
: PN#: 189-776L116
Date
: Jul 6 2016
Flash Firmware
Revision
: V1.42
CRC
: C0F4
P/N
: 189-776A142A
H/W parameters
Flash Memory Size
: 8 Mbytes
Flash Logos/Fonts
: 1600 kbytes
Flash User Storage
: 576 kbytes
Flash Perm’nt Fonts
: 2240 kbytes
Flash Journal Size
: 640 kbytes
SRAM Size
: 512 kbytes
Head settting
: H
Motor ID
: 1
Paper Type Setting
: Type 0, Monochrome
Color Density Adj
: n/a
Print Density, Mono
: 100%
Max Speed
: 300 mm/sec
Paper Width
: 80 mm
Max Power
: Level 1
Knife
: Enabled
Partial Cut
: 135 steps
Paper Low Sensor
: Enabled
No Paper Low Extension
Comm. Interface
Interface
: USB
RX Buffer Size
: 4096
USB Driver Type
: Printer Class
Interface
: RS232
RX Buffer Size
: 4096
Parameters
Baud Rate
: 115200
Data Bits
: 8
Stop Bit
: 1
Parity
: NONE
Flow Control
: DTR/DSR
Reception Errors
: Ignore
Resident Code Pages
: 437, 720, 737, 775, 850
852, 857, 858, 860, 862...
Press Feed Button Within the
Next Two Seconds
***To Enter Printer Config Menu***