Heater-Related Messages
The water flow is low – M016**
There may not be enough water flow through the heater to carry
the heat away from the heating element. Heater start up will
begin again after about 1 min. See “Flow Re-lated Checks”
below.
The water flow has failed* – M017**
There is not enough water flow through the heater to car-ry the
heat away from the heating element and the heater has been
disabled. See “Flow Related Checks” below. After the problem
has been resolved, reset the message*.
The heater may be dry* – M028**
Possible dry heater, or not enough water in the heater to start
it. The spa is shut down for 15 min. Reset this message* to
reset the heater start-up. See “Flow Related Checks” below.
The heater is dry* – M027**
There is not enough water in the heater to start it. The spa is
shut down. After the problem has been resolved, you must
reset the message* to restart heater start up. See “Flow
Related Checks” below.
The heater is too hot* – M030**
One of the water temp sensors has detected 118°f (47.8°C)
in the heater and the spa is shut down. You must reset the
message* when water is below 108°f (42.2°C). See “Flow
Related Checks” below.
Error
Message Code: 30
The heater is too hot
Flow-related checks
Check for low water level, suction flow restrictions, closed valves,
trapped air, too many closed jets and pump prime. On some
systems, even when spa is shut down by an error condition, some
equipment may occasionally turn on to continue monitoring
temperature or if freeze protection is needed.
* Some messages can be reset from the panel.
Messages that
can be reset will appear with a Clear Icon at the bottom of the
Message Screen. Press the Clear Icon text to reset the message.
**M0XX is a Message Code.
Codes like this will be seen in the Fault Log
Sensor-Related Messages
Sensors are out of sync – M015**
The temperature sensors MAY be out of sync by 3°F. Call for
Service if this message does not disappear within a few minutes.
Sensors are out of sync -- Call for service* – M026**
The temperature sensors ARE out of sync. The fault above has
been established for at least 1 hour. Call for Service.
Sensor A Fault, Senor B Fault – Sensor A: M031**, Sensor B
M032**
A temperature sensor or sensor circuit has failed.
Call for Service.
Error
Message Code: 31
Sensor A Fault Call
for Service
3
3