background image

OWNER’S MANUAL

 

PURFIKT SPA

2021

 

14 

to  the  acrylic  surface  and  may  induce  an  effect  known 
as “crazing”. Crazing is not covered under spa limited warranty.

STAINLESS 

STEEL 

CONTROLS 

AND 

COMPONENTS ABOVE THE WATERLINE

To  preserve  the  stainless  steel  finish  of  the controls 
and  components  above  the  water  line,  we recommend  they 
be wiped  with  a  dry  soft    cloth  after  each use  of  your    spa.  
In  addition,  off-gas  your  spa  by  removing  the  cover 
for approximately  30  minutes multiple  times  per  week  (if 
not in  use)  and  after every shock treatment. 

CABINET CARE 

Never  spray  cabinets  with  a  high-pressure  garden 
hose or  pressure  washer  for  any  reason.  This  action 
may  induce  an  electrical  short  in  the    spa’s  electrical 
equipment.

CEDAR CABINET 

Our  cedar  cabinets  are  made  from  top  quality 
Western  Cedar  and  manufactured  and  stained  at  our 
factory.  With  proper  care  and  maintenance,  your  cedar 
cabinet  should maintain  its  beauty  for  many  years. 
Manufacturer recommends  touch-up  or  re-staining  of  the 
cabinet  every three  to  four  years  depending  on  your 
environment.  Contact 

your 

Dealer 

for 

re-staining 

procedures.

VINYL CABINET 

Vinyl  cabinets  are  made  of  a  rigid  polymer  that 
combines  the  durability  of  plastic  with  the  beauty  of  real 
wood.  This  cabinet  is  manufactured  so  that  it  won’t  crack, 
peel,  blister  or delaminate  even  after  prolonged  exposure  to 
the  elements.  We  recommend  wiping  the  cabinet  with 
a  soft  damp cloth  (or  sponge) using household  soap  or 
liquid  detergent and  rinsing  with  fresh  water  thoroughly. 
DO  NOT  use  abrasive  cleansers  or  material  as  this 
may  damage  the surface. 

SLATE CABINETS 

Optional  Slate  cabinets  are  custom-built  and  painted 
in  our  factory.  We  recommend  lightly  brushing  the  cabinet 
with  a  SOFT  bristle  brush  to  remove  any  dirt  or  stains. 
For  more  information  on  the  care  of  your  Slate 
cabinet,  please contact  your  Local Dealer. 

COVER CARE 

A  well  cared  for  spa  cover  is  a  thing  of  beauty  in  its  own 
right.  Be  sure  to  clean  and  condition  your  cover  at  least 
once  a month (more  often  if  needed).

WEATHERSHEILD  COVER  MAINTAINANCE  PROCEDURE

 

Weather-shield is a solution dyed polyester fabric designed to be 
flexible  and  easy  for  manufacturers  to  use.  Its  urethane  coating 
enhances the stability of the weave and allows for greater water 
resistance,  while  also  minimizing  shrinkage  and  stretching. 
Weather-shield  features  a  high  UV,  water  and  mold  and  mildew 
resistance and has excellent tear and abrasion resistance.

CARE & CLEANING

Weather  Shield  is  designed  to  be  easy  to  maintain.  It  can  be 
washed,  or  brushed  off  and  rinsed.  Proper  care  and  cleaning  is 
important to the life of all fabrics.

FOR NORMAL CARE AND CLEANING

Add 2 ounces of mild soap such as Woolite or Dawn 

dish-

washing

 liquid to 1 gallon of lukewarm water.

Clean the fabric with a "soft bristle brush."

Rinse thoroughly with cold water and air dry.

FOR STUBBORN STAINS

Add maximum 1 cup of bleach to one 1 gallon of water.

Spray on lightly to the fabric face (non-coated side). Do not

soak fabric.

Prolonged  exposure  to  harsh  chemicals  can  damage  the

coating.

Rinse  immediately.  Do  not  leave  on  for  more  than  2

minutes.

Cleaning  with  harsh  cleaners  such  as  bleach  will  require  a 
re-treatment  like  303  High  Tech  Fabric  Guard  for  restoring 
water

 

repellency.

All  waterfalls  and  laminar  flow  water  features  should  be  turned 
off when the spa is not in use to avoid heat and water loss.

BASIC INSTALLATION AND CONFIGURATION 
GUIDELINES

WARNING!  Qualified  Technicians  Required  for  Service 
and Installation

ELECTRICAL REQUIREMENTS

All  self  contained  spas  use  120VAC  or  240VAC  electrical spa 
packs.  These  instructions  describe  the  only  acceptable electrical 
wiring  procedures.  Spas  wired  in  any  other  way  will void  your 
warranty  and  may  result  in  serious  injury.  All installations  should 
be completed by a certified electrician. Failure to comply with state 
and local codes may result in fire or personal injury and will be the 
sole responsibility of the spa owner. 

Содержание Purfikt Spa

Страница 1: ...Coast Spas Manufacturing 6315 202 Street Langley BC Canada V2Y 1N1 info coastspas com www coastspas com 2021 Owner s Manual Purfikt Spa ...

Страница 2: ...OWNER S MANUAL PURFIKT SPA 2021 2 ...

Страница 3: ...a selling dealer if you have any queries related to your Purfikt spa Coast Spas authorized dealers are trained professionals who can assist you with spa parts setup operations maintenance and technical support CONGRATULATIONS YOU RE ALMOST READY TO ENJOY YOUR NEW SPA Before you begin to enjoy your spa please take a moment to submit your spa warranty For registering your spa you will need the spa s...

Страница 4: ...ed by the supplier of the true variable speed pumps the Siemens brand GFCI can filter electrical spikes and avoid false trips The use of a 60 Amp Siemens GFCI is recommended with the Atlas System Glossary of terms Preparation set up and location of your new spa Spa general layout Spa features and specifications Start Up Guide Infinity Edge Spas Spa Care Guide Basic installation and configuration g...

Страница 5: ...ill require either a 40 50 or 60 Amp dedicated circuit breaker with the proper wire size gauge based on the length of the run The electrical circuit must be installed by a certified electrician and approved by a local building or electrical inspector Surface Transport Your new spa has left the factory cleaned and polished and ready to begin operation after passing our many quality and operational ...

Страница 6: ...rs not smaller than No 6 AWG when spa use exceeds 10 minutes Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C If pregnant please consult your physician before using a spa Before entering the spa the user should measure the water temperature wit...

Страница 7: ...ll help to discourage unsupervised children from entering the spa and keep the spa cover secure in high wind conditions There is no representation that the cover clip tie downs or actual locks will prevent access to the spa CAUTION For exercise the water should not exceed 90 F 32 C GLOSSARY OF TERMS AIR CONTROL Mounted generally on the lip of the spa it induces warm air from the equipment enclosur...

Страница 8: ...able high intensity hydrotherapy jet VOLCANO JET high output jet designed for foot and leg massage FUSION JETS Coast Spas Fusion Jets provide a seamless and smooth surface to relax against while you enjoy a therapeutic massage from various jet types all positioned to maximize hydrotherapy Digital Float and Fill Gauge The illuminated fill gauge for all Cascade Series Spas takes the guesswork out of...

Страница 9: ...agram below Spacing the straps may require slight adjustments to ensure the load is balanced The chains attached to the crane must be a minimum of 18 feet in length from the point of lifting Using chains smaller than 18 feet will add stress to the outer lip of the spa and may result in damage Using the appropriately weighted straps and chains is important to ensure the safe handling of the PURFIKT...

Страница 10: ...1 Volcano Jet 12 Ozone Cluster 13 5 Spa Light 14 Skimmers 15 Spa LED 16 Air Relief DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any swim spa designs and or features without notification To check on updates or for other information please visit www coastspas com DISCLAIMER The pictures displayed above are for referenc...

Страница 11: ...em but it also removes the dirty filter canisters from the bathing area Patented Technology and Design Always Perfect In a Coast Spas Cascade Series Spa the water level will always stay the same regardless of how many people are in the Spa Largest Skimmers Coast spas is proud to offer the largest skimmer in the industry this allows our Spas to remove debris from the surface of the Spa and help to ...

Страница 12: ...for 60 seconds Continue running pumps 2 3 pump 2 on 2 pump models turn pump 1 on high speed for 20 seconds by pressing the pump 1 icon twice Continue running pumps 2 3 pump 2 on 2 pump models on high speed for 30 seconds and activate pump 1 on high speed for 20 seconds Cascade check valve inside the equipment area full of water is an indication of no more air in the plumbing line If the check valv...

Страница 13: ...balanced spa water If you suspect that your chemicals may be unbalanced remove your pillows immediately until the water has been restored to suggested conditions Do not sit on the pillows Do not pull on the pillows Pillows should be cleaned using a soft cloth and mild soap then wiped with a conditioner We recommend that pillows be washed each time you drain you spa This Limited Warranty is void if...

Страница 14: ...l cared for spa cover is a thing of beauty in its own right Be sure to clean and condition your cover at least once a month more often if needed WEATHERSHEILD COVER MAINTAINANCE PROCEDURE Weather shield is a solution dyed polyester fabric designed to be flexible and easy for manufacturers to use Its urethane coating enhances the stability of the weave and allows for greater water resistance while ...

Страница 15: ...mum 6AWG copper conductors only Torque field connections between 21 and 23 lbs Readily accessible disconnecting means to be provided at time of installation Permanently connected power supply Connect only to a circuit protected by a Class A Ground Fault Circuit Interrupter GFCI or Residual Current Device RCD mounted at least 5 1 52M from the inside walls of the spa and in line of sight from the eq...

Страница 16: ...horized dealer to purchase suitable lubricant Place clean Cartridge in filter canister Replace filter lid and re tighten retaining ring finger tight only Note Make sure the O ring is on the air relief valve and is finger tight prior to starting the pump This O ring should periodically be lubricated with a silicone lubricant There is a 3 8 clear line coming from the filter area and this goes to the...

Страница 17: ...maintenance you can do for yourself Total Alkalinity This refers to the ability of the spa water to resist changes in pH Controlling alkalinity can help keep your pH in the appropriate range thereby lessening the need for pH balancing If the TA is too low the pH level will fluctuate rapidly from high to low If the TA is too high the pH will tend to be too high and will be very difficult to bring b...

Страница 18: ...too low High metal content in water Adjust alkalinity Adjust pH Use stain and scale product Poor filtration pH is too high Hardness is too high Total alkalinity is too high Suspended particles Clean filter cartridge Adjust pH Adjust hardness Adjust total alkalinity Drain and refill spa water pH is too high Sanitizer is too low Adjust pH Shock spa with sanitizer Adjust sanitizer level pH is too low...

Страница 19: ...ing constantly will not turn off Filter cycle set to 24 hours Problem with the circuit board Turn off 24 hour filtration Turn power off at GFCI and contact your Dealer Pump will not turn on GFCI tripped Motor has overheated Not plugged in Damaged plug Seized motor Blown fuse Motor vent is blocked Reset the GFCI Let cool for 1 hour Plug in to the board Contact your Dealer Contact your Dealer Check ...

Страница 20: ...of time in cold weather cold wind Spa is wired for 110V and jets are on Put cover back onto spa and allow for heat to regenerate Call your dealer if temperature does not increase Spa wired for 110V only have enough power to heat or operate pumps Turn off jets to power heater PUMPS WILL NOT PRIME PROBABLE CAUSE RECOMMENDED ACTION Pump on but no water flow Air trapped in pump No water in the pump Cl...

Страница 21: ...ould drain your spa to avoid accidental freezing caused by power outages Your local dealer can perform the following winterizing procedures if you are not completely comfortable with them Ensure that you have fully drained the spa Refer to the DRAINING YOUR SPA section After draining your spa may still have water remaining in the equipment and plumbing fittings Disconnect the hand tightened union ...

Страница 22: ...formation Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com Waterfall Shutoff General Note ON OFF BLUE PURFIKT JET Note Cluster Jet Poly Jet Storm Jet Volcano Jet Ø PT V T ...

Страница 23: ... will automatically go into sleep mode which turns the display off This is normal operation Touch anywhere on the screen to wake the panel up PURFIKT SPA CONTROL PANEL The Main Screen Lights Time Filter Cycle 1 Running Wi Fi Signal Indicator Lock Invert Screen High Temperature Range Heat Settings Temperature Scale F C Jets Set Temperature Clean up Cycle Ozone Running R Ready Mode RR Ready Rest Mod...

Страница 24: ...oing on Exiting the System information Screen will take you back to the Message Screen in that situation OWNER S MANUAL PURFIKT SPA 2021 24 Adjust set temperature lower on inactive fatal error Spa can t function until it s fixed Normal Error or Warning Reminder Message Information Message disabled Message waiting indicator The Message Waiting Indicator will show ne of the following icons Adjust se...

Страница 25: ...ment Below are some examples of 2 speed Pump indicators If the Spa has a Circ Pump a Circ Pump Icon will appear to indicate its activity but outside of Priming Mode the Circ Pump cannot be controlled directly One exception The Main Spa Light is not shown on the Spa Screen it is only shown and controlled on the Main Screen Jets Off Jets Low Jets High Common Buttons If an Up or Down button is shown ...

Страница 26: ...etting Each range maintains its own set temperature as programmed by the user This way when a range is chosen the spa will heat to the set temperature associated with that range High Range can be set between 80 F and 104 F Low Range can be set between 50 F and 99 F More specific Temp Ranges may be determined by the Manufacturer Freeze Protection is active in either range Heat Mode Ready vs Rest Ci...

Страница 27: ...on as the Priming Mode screeen appears on the panel select the Jets 1 button once to start Pump 1 in low speed and then again to switch to high speed Also select the other pumps to turn them on The pumps should be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not flowing from the jets in the spa do not allow the pumps to continue to run Turn ...

Страница 28: ...ystems the ozone will generally run with the circ pump but can be limited to filtration cycles On some circs systems Pump 1 low will run along with the circ Pump during filtration The system is factory programmed with one filter cycle that will run in the evening assuming the time of day is prop erly set when energy rates are often lower The filter time and duration are programmable A second filte...

Страница 29: ...l initiate a purge when Filter Cycle 2 is programmed to begin The Meaning of Filter Cycles 1 The heating pump always runs during the filter cycle 2 In Rest Mode heating only occurs during the filter cycle 3 Purges happen at the start of each filter cycle For example if your spa is set up for 24 hour circulation except for shutting off when the water temperature is 3 F 1 3 C above the set temperatu...

Страница 30: ...de Drain Mode Some spas have a special feature that allows Pump 1 to be employed when draining the water When available this feature is a component of Hold Mode M0XX is a Message Code Codes like this will be seen in the Fault Log Utilities The Utilities Icon on the Settings Screen takes you to the Utilities Screen The Utilities Screen contains the following Panel Touching the Panel Icon on the Uti...

Страница 31: ... can be used to reset the automatic test feature Units Screen The Units Icon on the Settings Screen takes you to the Units Screen Reminders The Reminder Icon on the Settings Screen takes you to the Reminders screen 1 Press Temp Display to change the temperature between Fahrenheit and Celsius 2 Press Time Display to change the clock between 12 hr and 24 hr display Press Reminders to turn the remind...

Страница 32: ...CI must be reset once it has tripped After passing the GFCI Trip Test any subsequent GFCI trips will indicate a ground fault or other unsafe condition and the power to the spa must be shut off until a service person can correct the problem Touching the GFCI Test Icon on the Utilities Screen takes you to the GFCI Test screen CE Product CE registered systems do not have an RCD Test Feature due to th...

Страница 33: ... and the spa is shut down You must reset the message when water is below 108 f 42 2 C See Flow Related Checks below Error Message Code 30 The heater is too hot Flow related checks Check for low water level suction flow restrictions closed valves trapped air too many closed jets and pump prime On some systems even when spa is shut down by an error condition some equipment may occasionally turn on t...

Страница 34: ...The GFCI or RCD is an important safety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function Change the water May appear on a regular schedule i e every 90 days Change the water in th...

Страница 35: ... Spa can be controlled by using the Balboa Worldwide App bwaTM that allows you to access your spa via a direct connection anywhere in the local proximity of your tub anywhere in your house that you can connect to your local Wi Fi network or anywhere in the World you have an Internet connection to your smart device via 3G 4G or Wi Fi The bwaTM app can be downloaded from Google play store or Apple A...

Страница 36: ..._________________ _____________________________________________________________ ____________________ _____________________________________________________________ ____________________ _____________________________________________________________ ____________________ _____________________________________________________________ ____________________ __________________________________________________...

Страница 37: ...______________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ ___________________________________________...

Страница 38: ...38 WORLD S BEST BUILT SPAS ...

Отзывы: