Setting the time-of-day is important for determining filtration
times and other background features.
The Heat Icon
on the Settings Screen takes you to a
screen where you control the Time-of-Day.
On the Time-of-Day screen, simply select the Hours and
Minutes. Use the Up and Down Buttons to make changes,
then Save.
OWNER’S MANUAL
PURFIKT SPA
2021
Non-Circ Systems
The low-speed of pump 1 runs when the blower or any
other pump is on. If the spa is in Ready Mode (See page 11),
Pump 1 low may also activate for at least 1 minute every 30
minutes to detect the spa temperature (polling) and then to
heat to the set temperature if needed. When the low-
speed turns on automatically, it cannot be deactivated from
the panel, however the high speed may be started.
Circulation Pump Modes
If the system is equipped with a circ pump, it will
be configured to work in one of three different ways:
1. The circ pump operates continuously (24 hours) with the
exception of turning off for 30 minutes at a time when the
water temperature reaches 3°F (1.5°C) above the set
temperature (most likely to happen in very hot climates).
2. The circ pump stays on continuously, regardless of water
temperature.
3. A pogrammable circ pump will come on when the system
is checking temperature (polling), during filter cycles,
during freeze conditions, or when another pump is on. The
specific Circulation Mode that is used has been
determined by the Manufacturer and cannot be changed in
the field.
Other device options may be available, like Blower, Light,
Mister, etc.
Filtration and Ozone
On non-circ systems, Pump 1 low and the ozone generator will
run during filtration. On circ systems, the ozone will generally
run with the circ pump, but can be limited to filtration cycles.
(On some circs systems, Pump 1 low will run along with the circ
Pump during filtration.)
The system is factory-programmed with one filter cycle that will
run in the evening (assuming the time-of-day is prop-erly set)
when energy rates are often lower. The filter time and duration
are programmable. A second filter cycle can be enabled as
needed.
At the start of each filter cycle, the water devices like blower,
mister device (if these exist) and other pumps will run briefly to
purge the plumbing to maintain good water quality.
Freeze Protection
If the temperature sensors within the heater detect a low enough
temperature, then the water devices automatically activate to
provide freeze protection. The water devices will run either
continuously or periodically depending on conditions.
In colder climates, an optional freeze sensor may be added to
protect against freeze conditions that may not be sensed by
the standard sensors. Auxiliary freeze sensor protec-tion
acts similarly except with the temperature thresholds
determined by the switch. See your dealer for details.
Clean-up Cycle (optional)
When a pump or blower is turned on by a button press, a
clean-up cycle begins 30 minutes after the pump or blower is
turned off or times out. The pump and the ozone
generator will run for 30 minutes or more, depending on the
system. On some systems, you can change this setting.
Time of Day
Be sure to set the Time-of-Day
9:16
am
If no Time-of-Day is set...
In the memory an Information Screen will appear. If you exit it
and Information Icon will appear at the bottom of the Main
Screen, until the time-of-day has been set.
NOTE:
This only applies to some systems:
If power is interrupted to the system, Time-of-Day will be
maintained for several days.