background image

Quick Reference Card

The 

Quick Reference Card

 provides a quick overview of your spa's main

functions and the operations accessible with your digital control pad.

Press 

Pump 1 

to turn Pump 1 on at low speed.

Press a second time to turn pump to high speed.

Press a third time to turn pump off. When at high

speed, a built-in timer turns pump off after 20 min-

utes and when at low speed after 2 hours, unless

manually deactivated first.
 

The "Pump 1" indicator lights up

 

when Pump 1 is on at high speed.

 

It flashes when Pump 1 is on at low

 

speed.

Starting Pump 1:

Press and hold 

Light

 key for 5 seconds to display

water temperature in either Fahrenheit (˚F) or

Celsius (˚C). If a power-up occurs, system re-

turns to default setting (˚F).

Temperature display unit:

Press 

Econo

 key to switch from Normal mode to

Economy mode. In Economy mode, system main-

tains temperature at the desired Set Point during

filter cycles only. Set Point is 20˚F (11˚C) below

the Normal mode Set Point for the rest of the

time. In Economy mode, the display will toggle

between the current water temperature and the

"Econ" message.

Economy mode:

SC-MP-DY1 / Dual-Pump System

Press 

Light

 to turn light on. Pressing a second time

turns light off. A built-in timer automatically turns light

off after 2 hours, unless manually deactivated first.
 

The "Light" indicator is displayed

 

when light is on.

Fiber Box Option:

 If spa has an optional fiber box,

press 

Light

 key to turn fiber box (motor and light)

on. Pressing a second time turns fiber box off but

leaves light on. A third time turns both motor and

light off. A built-in timer turns fiber box off after 

2 hours, unless it has been manually deactivated. 

The "Light" icon is displayed when fiber box light 

is on. It flashes when fiber box motor and light 

are on at the same time.

Turning the light on:

Press 

Pump 2

 to turn Pump 2 on. Press a second

time to turn Pump 2 off. A built-in timer automati-

cally turns pump off after 20 minutes, unless pump

has been manually deactivated.
 

The "Pump 2" indicator lights up

 

when Pump 2 is on.

Starting Pump 2:

Use 

Up

 or 

Down

 arrow keys to regulate water

temperature. The temperature setting will be

displayed for 5 seconds to confirm your new

selection.
 

The "Set Point" indicator displays the

 

desired temperature, NOT the current

 

water temperature!

Water temperature can be adjusted by 1˚ in-

crements from 59 to 104˚F (15 to 40˚C).

Setting water temperature:

When water temperature is 1˚F (0.5˚C) lower

than the Set Point, the heater will automatically

turn on until water temperature reaches Set Point

plus 1˚F (0.5˚C).
 

The "Heater" indicator lights up when

 

the heater is on. It flashes when there

 

is a request for more heat but the heater

 

has not yet started.

N.B.: If your system is configured in Low Current Mode,

the heater will not start if a pump is on at high speed.

Automatic water heater start: