background image

OWNER’S MANUAL

 

PURFIKT SPA

2021

 

Circulation Mode

If  the  spa  is  configured  for  24HR  circulation,  the heater 
pump  generally  runs  continuously.  Since  the heater  pump 
is always running, the spa will maintain set temperature and 
heat  as  needed  in  Ready  Mode,  without  polling. 
In  Rest  Mode,  the  spa  will  only  heat  to  set  temperature 
during  programmed  filter  times,  even  though  the  water  is 
being filtered constantly when in 24HR circulation mode.

Ready-in-Rest Mode

Ready in Rest Mode appears in the display if the spa is in Rest 
Mode and the Jets 1 Button is pressed. When the heater pump 
has  come  on  automatically  (for  ex-ample  for  heating)  you  can 
switch between low speed and high speed but you cannot turn 
the heater pump off. After 1 hour, the System will revert to Rest 
Mode. This mode can also be reset by selecting the Heat Mode 
line on the Screen shown here.

Fill it up! 

Preparation & Filling

Fill  the  spa  to  its  correct  operating  level.  Be  sure to  open  all 
valves  and  jets  in  the  plumbing  system  before  filling  to  allow 
as  much  air  as  possible  to  escape  from  the  plumbing  and 
the  control  system during the filling process.
After  turning  the  power  on  at  the  main  power  panel, the 
top-side panel will display a splash screen or startup screen.

Priming Mode – M019*

After the initial start-up sequence, the control will  enter Priming 
Mode  and  display  a  Priming  Mode  screen.  Only  pump  icons 
appear  on  the  priming mode screen. During the priming mode, 
the  heater  is    disabled  to  allow  the  priming  process  to  be 
complet-ed without the possibility of energizing the heater under 
low-flow or no-flow conditions. Nothing comes on automatically, 
but the pump(s) can be energized by selecting the “Jet” buttons. 
If  the  spa  has  a  Circ  Pump,  it  can  be  turned  on  and  off  by 
pressing the “Circ” button during Priming Mode.

Priming the Pumps

As  soon  as  the  Priming  Mode  screeen  appears  on  the  panel, 
select the “Jets 1” button once to start Pump 1 in low-speed and 
then  again  to  switch  to  high-speed.  Also,  select  the  other 
pumps, to turn them on. The pumps should be running in high-
speed to facilitate priming. If the pumps have not primed after 2 
minutes, and water is not flowing from the jets in the spa, do not 
allow  the  pumps  to  continue  to  run.  Turn  off  the  pumps  and 

repeat the process.

Note: 

Turning  the  power  off  and  back  on  again  will  initiate  a  new 

pump priming session. Sometimes momentarily turning the pump off 
and on will help it to prime. Do not do this more than 5 times. If the 
pump(s)  will  not  prime,  shut  off  the  power  to  the  spa  and  call  for 
service. 

Important: 

A pump should not be allowed to run without priming 

for more than 2 minutes. Under NO circumstances should a pump 
be allowed to run without priming beyond the end of the 4-5 minute 
priming mode. Doing so may cause damage to the pump and 
cause the system to energize the heater and go into an overheat 
condition.

Exiting Priming Mode

The system will automatically enter the normal heating and filtering 
at the end of the priming mode, which lasts 4-5 minutes. 

You  can  manually  exit  Priming  Mode  by  pressing  the  “Back” 
button  on  the  Priming  Mode  Screen.  Note  that  if  you  do  not 
manually  exit  the  priming  mode  as  described  above,  the 
priming mode will be automatically terminated  after 4-5 minutes. 
Be sure that the pump(s) have been primed by this time. 

–– – –

°F

 

– – – –

°C

Once  the  system  has  exited  Priming  Mode,  the  top-side  panel 
will display  the  Main  Screen,  but  the  display  will  not  show 
the water  temperature  yet,  as  shown  below.  This  is  because 
the  system  requires  approximately  1  minute  of  water  flowing 
through  the  heater  to  determine  the  water  temperature  and 
display it. 

*M0XX is a Message Code.

Spa Behavior 

Pumps

On the Spa Screen, select a “Jets” button once to turn the pump 
on or off, and to shift between low- and high-speeds if equipped. If 
left running, the pump will turn off after a time-out period.

2

7

Содержание Purfikt Spa

Страница 1: ...Coast Spas Manufacturing 6315 202 Street Langley BC Canada V2Y 1N1 info coastspas com www coastspas com 2021 Owner s Manual Purfikt Spa ...

Страница 2: ...OWNER S MANUAL PURFIKT SPA 2021 2 ...

Страница 3: ...a selling dealer if you have any queries related to your Purfikt spa Coast Spas authorized dealers are trained professionals who can assist you with spa parts setup operations maintenance and technical support CONGRATULATIONS YOU RE ALMOST READY TO ENJOY YOUR NEW SPA Before you begin to enjoy your spa please take a moment to submit your spa warranty For registering your spa you will need the spa s...

Страница 4: ...ed by the supplier of the true variable speed pumps the Siemens brand GFCI can filter electrical spikes and avoid false trips The use of a 60 Amp Siemens GFCI is recommended with the Atlas System Glossary of terms Preparation set up and location of your new spa Spa general layout Spa features and specifications Start Up Guide Infinity Edge Spas Spa Care Guide Basic installation and configuration g...

Страница 5: ...ill require either a 40 50 or 60 Amp dedicated circuit breaker with the proper wire size gauge based on the length of the run The electrical circuit must be installed by a certified electrician and approved by a local building or electrical inspector Surface Transport Your new spa has left the factory cleaned and polished and ready to begin operation after passing our many quality and operational ...

Страница 6: ...rs not smaller than No 6 AWG when spa use exceeds 10 minutes Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C If pregnant please consult your physician before using a spa Before entering the spa the user should measure the water temperature wit...

Страница 7: ...ll help to discourage unsupervised children from entering the spa and keep the spa cover secure in high wind conditions There is no representation that the cover clip tie downs or actual locks will prevent access to the spa CAUTION For exercise the water should not exceed 90 F 32 C GLOSSARY OF TERMS AIR CONTROL Mounted generally on the lip of the spa it induces warm air from the equipment enclosur...

Страница 8: ...able high intensity hydrotherapy jet VOLCANO JET high output jet designed for foot and leg massage FUSION JETS Coast Spas Fusion Jets provide a seamless and smooth surface to relax against while you enjoy a therapeutic massage from various jet types all positioned to maximize hydrotherapy Digital Float and Fill Gauge The illuminated fill gauge for all Cascade Series Spas takes the guesswork out of...

Страница 9: ...agram below Spacing the straps may require slight adjustments to ensure the load is balanced The chains attached to the crane must be a minimum of 18 feet in length from the point of lifting Using chains smaller than 18 feet will add stress to the outer lip of the spa and may result in damage Using the appropriately weighted straps and chains is important to ensure the safe handling of the PURFIKT...

Страница 10: ...1 Volcano Jet 12 Ozone Cluster 13 5 Spa Light 14 Skimmers 15 Spa LED 16 Air Relief DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any swim spa designs and or features without notification To check on updates or for other information please visit www coastspas com DISCLAIMER The pictures displayed above are for referenc...

Страница 11: ...em but it also removes the dirty filter canisters from the bathing area Patented Technology and Design Always Perfect In a Coast Spas Cascade Series Spa the water level will always stay the same regardless of how many people are in the Spa Largest Skimmers Coast spas is proud to offer the largest skimmer in the industry this allows our Spas to remove debris from the surface of the Spa and help to ...

Страница 12: ...for 60 seconds Continue running pumps 2 3 pump 2 on 2 pump models turn pump 1 on high speed for 20 seconds by pressing the pump 1 icon twice Continue running pumps 2 3 pump 2 on 2 pump models on high speed for 30 seconds and activate pump 1 on high speed for 20 seconds Cascade check valve inside the equipment area full of water is an indication of no more air in the plumbing line If the check valv...

Страница 13: ...balanced spa water If you suspect that your chemicals may be unbalanced remove your pillows immediately until the water has been restored to suggested conditions Do not sit on the pillows Do not pull on the pillows Pillows should be cleaned using a soft cloth and mild soap then wiped with a conditioner We recommend that pillows be washed each time you drain you spa This Limited Warranty is void if...

Страница 14: ...l cared for spa cover is a thing of beauty in its own right Be sure to clean and condition your cover at least once a month more often if needed WEATHERSHEILD COVER MAINTAINANCE PROCEDURE Weather shield is a solution dyed polyester fabric designed to be flexible and easy for manufacturers to use Its urethane coating enhances the stability of the weave and allows for greater water resistance while ...

Страница 15: ...mum 6AWG copper conductors only Torque field connections between 21 and 23 lbs Readily accessible disconnecting means to be provided at time of installation Permanently connected power supply Connect only to a circuit protected by a Class A Ground Fault Circuit Interrupter GFCI or Residual Current Device RCD mounted at least 5 1 52M from the inside walls of the spa and in line of sight from the eq...

Страница 16: ...horized dealer to purchase suitable lubricant Place clean Cartridge in filter canister Replace filter lid and re tighten retaining ring finger tight only Note Make sure the O ring is on the air relief valve and is finger tight prior to starting the pump This O ring should periodically be lubricated with a silicone lubricant There is a 3 8 clear line coming from the filter area and this goes to the...

Страница 17: ...maintenance you can do for yourself Total Alkalinity This refers to the ability of the spa water to resist changes in pH Controlling alkalinity can help keep your pH in the appropriate range thereby lessening the need for pH balancing If the TA is too low the pH level will fluctuate rapidly from high to low If the TA is too high the pH will tend to be too high and will be very difficult to bring b...

Страница 18: ...too low High metal content in water Adjust alkalinity Adjust pH Use stain and scale product Poor filtration pH is too high Hardness is too high Total alkalinity is too high Suspended particles Clean filter cartridge Adjust pH Adjust hardness Adjust total alkalinity Drain and refill spa water pH is too high Sanitizer is too low Adjust pH Shock spa with sanitizer Adjust sanitizer level pH is too low...

Страница 19: ...ing constantly will not turn off Filter cycle set to 24 hours Problem with the circuit board Turn off 24 hour filtration Turn power off at GFCI and contact your Dealer Pump will not turn on GFCI tripped Motor has overheated Not plugged in Damaged plug Seized motor Blown fuse Motor vent is blocked Reset the GFCI Let cool for 1 hour Plug in to the board Contact your Dealer Contact your Dealer Check ...

Страница 20: ...of time in cold weather cold wind Spa is wired for 110V and jets are on Put cover back onto spa and allow for heat to regenerate Call your dealer if temperature does not increase Spa wired for 110V only have enough power to heat or operate pumps Turn off jets to power heater PUMPS WILL NOT PRIME PROBABLE CAUSE RECOMMENDED ACTION Pump on but no water flow Air trapped in pump No water in the pump Cl...

Страница 21: ...ould drain your spa to avoid accidental freezing caused by power outages Your local dealer can perform the following winterizing procedures if you are not completely comfortable with them Ensure that you have fully drained the spa Refer to the DRAINING YOUR SPA section After draining your spa may still have water remaining in the equipment and plumbing fittings Disconnect the hand tightened union ...

Страница 22: ...formation Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com Waterfall Shutoff General Note ON OFF BLUE PURFIKT JET Note Cluster Jet Poly Jet Storm Jet Volcano Jet Ø PT V T ...

Страница 23: ... will automatically go into sleep mode which turns the display off This is normal operation Touch anywhere on the screen to wake the panel up PURFIKT SPA CONTROL PANEL The Main Screen Lights Time Filter Cycle 1 Running Wi Fi Signal Indicator Lock Invert Screen High Temperature Range Heat Settings Temperature Scale F C Jets Set Temperature Clean up Cycle Ozone Running R Ready Mode RR Ready Rest Mod...

Страница 24: ...oing on Exiting the System information Screen will take you back to the Message Screen in that situation OWNER S MANUAL PURFIKT SPA 2021 24 Adjust set temperature lower on inactive fatal error Spa can t function until it s fixed Normal Error or Warning Reminder Message Information Message disabled Message waiting indicator The Message Waiting Indicator will show ne of the following icons Adjust se...

Страница 25: ...ment Below are some examples of 2 speed Pump indicators If the Spa has a Circ Pump a Circ Pump Icon will appear to indicate its activity but outside of Priming Mode the Circ Pump cannot be controlled directly One exception The Main Spa Light is not shown on the Spa Screen it is only shown and controlled on the Main Screen Jets Off Jets Low Jets High Common Buttons If an Up or Down button is shown ...

Страница 26: ...etting Each range maintains its own set temperature as programmed by the user This way when a range is chosen the spa will heat to the set temperature associated with that range High Range can be set between 80 F and 104 F Low Range can be set between 50 F and 99 F More specific Temp Ranges may be determined by the Manufacturer Freeze Protection is active in either range Heat Mode Ready vs Rest Ci...

Страница 27: ...on as the Priming Mode screeen appears on the panel select the Jets 1 button once to start Pump 1 in low speed and then again to switch to high speed Also select the other pumps to turn them on The pumps should be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not flowing from the jets in the spa do not allow the pumps to continue to run Turn ...

Страница 28: ...ystems the ozone will generally run with the circ pump but can be limited to filtration cycles On some circs systems Pump 1 low will run along with the circ Pump during filtration The system is factory programmed with one filter cycle that will run in the evening assuming the time of day is prop erly set when energy rates are often lower The filter time and duration are programmable A second filte...

Страница 29: ...l initiate a purge when Filter Cycle 2 is programmed to begin The Meaning of Filter Cycles 1 The heating pump always runs during the filter cycle 2 In Rest Mode heating only occurs during the filter cycle 3 Purges happen at the start of each filter cycle For example if your spa is set up for 24 hour circulation except for shutting off when the water temperature is 3 F 1 3 C above the set temperatu...

Страница 30: ...de Drain Mode Some spas have a special feature that allows Pump 1 to be employed when draining the water When available this feature is a component of Hold Mode M0XX is a Message Code Codes like this will be seen in the Fault Log Utilities The Utilities Icon on the Settings Screen takes you to the Utilities Screen The Utilities Screen contains the following Panel Touching the Panel Icon on the Uti...

Страница 31: ... can be used to reset the automatic test feature Units Screen The Units Icon on the Settings Screen takes you to the Units Screen Reminders The Reminder Icon on the Settings Screen takes you to the Reminders screen 1 Press Temp Display to change the temperature between Fahrenheit and Celsius 2 Press Time Display to change the clock between 12 hr and 24 hr display Press Reminders to turn the remind...

Страница 32: ...CI must be reset once it has tripped After passing the GFCI Trip Test any subsequent GFCI trips will indicate a ground fault or other unsafe condition and the power to the spa must be shut off until a service person can correct the problem Touching the GFCI Test Icon on the Utilities Screen takes you to the GFCI Test screen CE Product CE registered systems do not have an RCD Test Feature due to th...

Страница 33: ... and the spa is shut down You must reset the message when water is below 108 f 42 2 C See Flow Related Checks below Error Message Code 30 The heater is too hot Flow related checks Check for low water level suction flow restrictions closed valves trapped air too many closed jets and pump prime On some systems even when spa is shut down by an error condition some equipment may occasionally turn on t...

Страница 34: ...The GFCI or RCD is an important safety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function Change the water May appear on a regular schedule i e every 90 days Change the water in th...

Страница 35: ... Spa can be controlled by using the Balboa Worldwide App bwaTM that allows you to access your spa via a direct connection anywhere in the local proximity of your tub anywhere in your house that you can connect to your local Wi Fi network or anywhere in the World you have an Internet connection to your smart device via 3G 4G or Wi Fi The bwaTM app can be downloaded from Google play store or Apple A...

Страница 36: ..._________________ _____________________________________________________________ ____________________ _____________________________________________________________ ____________________ _____________________________________________________________ ____________________ _____________________________________________________________ ____________________ __________________________________________________...

Страница 37: ...______________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ ___________________________________________...

Страница 38: ...38 WORLD S BEST BUILT SPAS ...