OWNER’S MANUAL
PURFIKT SPA
2021
15
CSA COMPLIANCE
CAUTION:
•
Test the ground fault circuit interrupter before each use
of the spa.
•
Read the instruction manual.
•
Adequate drainage must be provided if the equipment is
to be installed in a pit.
FOR USE ONLY WITHIN AN ENCLOSURE RATED
CSA ENCLOSURE 3. CONNECT ONLY TO A CIRCUIT
PROTECTED BY A CLASS A GROUND
FAULT
CIRCUIT
INTERRUPTER OR RESIDUAL CURRENT
DEVICE. TO ENSURE CONTINUED PROTECTION
AGAINST SHOCK HAZARD, USE ONLY IDENTICAL
REPLACEMENT PARTS WHEN SERVICING. INSTALL A
SUITABLY RATED SUCTION GUARD TO MATCH THE
MAXIMUM FLOW RATE MARKED.
120VA:
This requires an isolated 15 Amp circuit
breaker. This needs to be an isolated circuit with no other
appliances or lights on this circuit at any time. Extension cords
are not to be used in conjunction with the operations of the
spa. Low voltage damage could result and this is not covered by
warranty.
NOTE:
All components must be 120V; No 240V components
allowable.
2
4
0VA:
Depending on the model of spa, it will
require either a 40 Amp, 50 Amp, or 60 Amp dedicated circuit
breaker, GFCI, with the proper wire size based on the length
of the run. The electrical circuit must be installed by a
certified electrician and approved by a local building or electrical
inspector.
Use minimum 6AWG copper conductors only. Torque
field connections between 21 and 23
lbs. Readily
accessible disconnecting means to be provided at time of
installation. Permanently connected power supply.
Connect only to a circuit protected by a Class A Ground Fault
Circuit Interrupter (GFCI) or Residual Current Device (RCD)
mounted at least 5’ (1.52M) from the inside walls of the spa and in
line of sight from the equipment compartment.
CSA ENCLOSURE: TYPE 2
Refer to Wiring Diagram inside the cover of the control
enclosure. Refer to Installation and Safety Instructions provided
by the spa manufacturer.
WARNING!
GFCI or RCD Protection.
The Owner should test and reset the GFCI or RCD on a regular
basis to verify its function.04
WARNING!
Shock Hazard! No User Serviceable Parts.
Do not attempt service of this control system. Contact your dealer
or service organization for assistance. Follow all owner’s manual
power connection instructions. Installation must be performed by a
licensed electrician and all grounding connections must be
properly installed. Disconnect the electric power before servicing.
Keep access door closed.
SERIES
JETS
PUMPS
VOLTAGE
AMPERAGE
FREQUENCY
CIRCUIT
BREAKER
MAX FLOW
RATE
PURFIKT
39
2x 5HP
240
40
60
50
91
PURFIKT SPA AMP CHART
WARNING
•
Water temperature in excess of 38°C may be injurious to
your health.
•
Disconnect the electrical power before servicing.
CAUTION:
When using this electrical equipment, basic safety
precautions should always be followed.