V1.4 2019-09
Page 27 of 35
11.1
ID (Identify Unit)
Definition
The Identify command is used to permit a given unit to be physically identified.
It causes the Power LED on the unit to flash at an approximate rate of 330
milliseconds for ON and same for OFF.
Identify command has an ON / OFF parameter and remains in the selected state
until a new Identify command (or reset event) is sent to change state.
Syntax
ID <Space> <PARAM 1> <CR>
PARAM 1
Defines whether LED flashes
0 = OFF
1 = ON
PARAM 2
This parameter is not required. Carriage return shall follow immediately after
Parameter 1.
Example(s)
To set Identify on
Ex 1: ID 1<CR>
Device
response(s)
The following response shall be received from the device
Res 1: ACK ID 1<CR>
11.2
FU (Find Unit)
Definition
The Find Unit command is used to permit a given unit to be physically identified.
It causes the Power LED to flash at an approximate rate of 330 milliseconds for
ON and same for OFF.
The Find Unit command shall flash the Power LED for 5 seconds only after which
the Power LED function shall then resume without the need for sending any
additional commands.
Syntax
FU<CR>
PARAM 1
This parameter is not required. Carriage return shall follow immediately after
the Command.
PARAM 2
This parameter is not required.
Example(s)
To Find unit
Ex 1: FU<CR>
Device
response(s)
The following response shall be received from the device
Res 1: ACK FU<CR>