V1.4 2019-09
Page 9 of 35
3.3
Connecting to TIM-1000
To display TIM-1000’s web GUI, locate its Control port’s IP address and using a web browser connect
to it
http::/<Control IP address>/index.php
Default password for both Home and Advanced pages is “clockaudio”.
3.4
Adding additional units
For some room configurations, it may be desirable to have more than one TIM-1000. For this
scenario, it is possible to add other unit(s) to the room. There are two ways to cable these additional
units.
1.
Daisy-chain control path – For this option, from the first unit’s Control port 2 (CTRL 2) attach
a shielded Cat 5e cable to the control port (CTRL 1) on the second unit. If multiple units need
to be connected to cover a large area, then repeat the process of connecting CTRL 2 to the
next unit’s CTRL 1.
It is important to note that the PoE or Data Port cannot be daisy chained.
2.
Run separate cables – As per the first unit, separate cables for Data and Control can be run.
3.5
Coverage Area
These figures are typical and the coverage area will vary depending upon the install.
Typical height from floor level to TIM-1000 is 2.4m to 3.1m (8ft to 10ft).
Typical coverage area for TIM-1000 at this height is 9.1m (30ft) diameter.
Setting APT function to other than OFF can simulate a larger pickup area as the quieter sounds will
be uplifted.