en01c381.fm, 23.04.2009
P1934E/EN 2009-04
7
Getting started
1
1
Getting started
1.1
Workplace safety symbol
!
This warning sign identifies all notes on safe work practices in this operator's manual,
alerting to hazards to life and health of personnel. Observe these notes and proceed with
special care in the cases described. Pass all safety instructions on to other operators. In
addition to the safety instructions in these operating instructions, the general local safety
and accident prevention rules must be observed.
ATTENTION!
The signal word "Attention" identifies all portions of these operating instructions meriting
special attention to ensure that guidelines, rules, hints and the correct work procedures
are observed and to prevent damage to and destruction of the machine and/or parts.
1.2
Checking your unit
Take the time to ensure you have the required peripheral equipment and cables necessary to
setup and run your unit. If you do not have all the necessary items, contact your distributor.
Refer to Attachment A.1, page 12 for illustration of your unit.
1.3
Software
Your unit has been pre-loaded with software version 2.03.08 and requires no additional software
to begin your fastening process. If you are interfacing your unit with an external computer, inter-
facing software is required. Contact your distributor for the interfacing software.
1.4
Installing the unit
1.4.1
General information
!
It is mandatory that national, state and local safety and wiring standards be followed dur-
ing installation. These standards take precedence over any information presented in this
section.
To avoid the hazard of electrical shock or burn, the following instructions must be
adhered to. Failure to follow these instructions may also cause damage to your unit and
void existing warranties.
• Do not energize the unit until all connections have been properly made.
• Equipment must be properly grounded before applying power. Units energized by cord
and plug must be connected to an approved and properly grounded receptacle.
• All units must be energized by an isolated line.
• The unit door must always be closed and secured prior to energizing the unit.
• Ensure the power switch is in the "off" position prior to connecting the power cord.
•
ATTENTION!
Though it is not mandatory, the following instructions are highly recommended for the
protected operation of your unit.
• Use an isolation transformer and surge arrestor on the incoming isolated line.
• Use oversized feeder lines to reduce electrical noise and voltage drop.