Assemble the End Wall Framing
After the concrete has set, assemble the remainder of the
end wall.
• Angled brackets (QH1330)
• 1-way fittings (104624) and connectors (104643)
• 5/16" carriage bolts and nuts and Tek screws
(FA4482B)
• Band clamps (QH1402) and brackets (104074)
• 2" x 2" square tube (105328) and inserts (104075)
• 1.5" x 1.5" square tube (end wall frame)
NOTE:
The dashed lines in the diagram below show where
to install the 2" x 2" square tubes for the door frames.
Complete these steps to assemble the door frames for the
overhead doors of the end wall:
1. Using the door dimensions and the
2" x 2" square
tubing (105328)
, take two 105328 tubes and connect
them using a 104075 (1.75" x 1.75") square tube insert.
Install Tek screws to secure the splice. See below.
NOTE:
Consult the End Frame diagram to properly
position and connect the brackets.
2. Measure the required length for this first door jamb and
cut the assembled 2" x 2" frame member to length.
Before
you cut the tube, consult the diagram below to
account for the hardware that will be attached to the
upper end of
each door jamb
. Repeat for the remaining
2" x 2" door jamb.
3. After cutting the jambs to length, attach the 104074
brackets, place the band clamps over the lower chord
of the end rafter, and install the door jambs.
Insert a 1.75"
square tube
(104075) between
two (2) 2.00" pipes
and connect them
using Tek screws.
104075
2.00" x 2.00"
Pipe
2.00" x 2.00"
Pipe
Tek screws
End Frame-to-Rafter Exploded View
QH1402
Band Clamp
End Frame
Square Tube
104074
FAH320B 2-1/2"
Carriage Bolt
FALB32B
5/16" Nut
ATTENTION:
The lower end of each 2" x 2" main door
jamb slides over each 1.75" x 1.75" ground post set in
concrete. Secure the 2" x 2" jamb to the ground posts
by installing Tek screws.
Do not install Tek screws on
the front or back side of the vertical door frame tubes.
These surface are reserved for the end panels and the
door track when an overhead door is installed.
4. Assemble, cut and attach the 2" x 2" header.
5. Repeat the steps as needed to assemble the remaining
end wall framing using the 1.50" x 1.50" square tubing
(104779) and the related connectors. See dashed lines
below.
END WALL INSTALLATION (CONTINUED)
Ground Level
1.50" x 1.50" Tubes
2" x 2" Tubes
Ground Level
2" x 2" Tubes
Header
Door Jambs
chord