19
CLEARSPAN
™
STORAGE MASTER
Revision date: 05.08.19
ATTACH MAIN COVER
Gather the parts:
• Main cover (with conduits already inserted)
• Ropes long enough to reach over the frame (provided
by customer)
• Ratchets (QH1061) and 103620B straps
• Tek screws and utility knife (or similar cutting tool)
Assembly Procedure
1. Divide the remaining number of ratchets in half. Place
the ratchets on the ground next to the rafter where they
will be attached. See Side Profile diagram.
NOTE:
Ratchets are evenly spaced long each side of
the shelter and directly across from each other on the
same rafter assembly
. Rafters are identified by the
arrows above.
2. To pull the cover over the frame, attach ropes to both
ends of the cover conduit. Wrap the rope around the
conduit a few times to prevent it from slipping off.
3. With all ropes attached to the cover conduit, lift the
conduit and carry the cover toward the base of the
frame.
4. Toss the ropes over the frame and pull the cover into
position. One person is required at each rope.
5. Once the main cover is pulled into position, center the
cover on the frame and remove the ropes. Loosely
secure the ends of the cover to the ratchets
attached
to the base rail of the end wall framing (previous
procedure).
ATTENTION:
Do not tighten the straps at this time
6. Using the main cover conduit and strap length as
guides, attach the ratchets to the rafters at the proper
height. Fasten ratchets to the outside (or inside if
desired) of the rafters using Tek screws.
7. Lift the cover skirt and cut a slit in the cover conduit
pocket at the rafter position. Insert a 3' section of strap
through the slit and around the cover conduit.
Ropes
Cover
Conduit
Frame shown without end panels for clarity.
NOTE:
Depending on the length of the cover it may
be necessary to attach additional ropes to the cover
conduit between the end ropes by cutting a small
opening in the cover pocket and tying the rope around
the conduit. DO NOT cut through the main cover.
Cut
through the conduit pocket only.
NOTE:
DO NOT cut through the main cover.
Cut
through the conduit pocket only.