CLEARSPAN
™
STORAGE MASTER
18
Revision date: 05.08.19
a. Locate all sections of pipe needed to assemble
the cover conduit.
b. Insert the swaged end of each pipe into the
plain end of another pipe until the conduit is
assembled.
c. Secure each pipe joint with a Tek screw.
Cover Conduits
Cover
Ends w/
Strapping
Frame shown without end panels for clarity.
PREPARE MAIN COVER
Gather the parts:
• Main cover
• Pipe 1.315" x 75" swaged
• Pipe 1.315" x 73.5" plain
• Ratchets (QH1061)
• Tek screws
Assembly Procedure
NOTE:
When handling the main cover and setting it in
position, do not pull on the end straps. They will pull out of
the cover.
WARNING:
To prevent damage to the cover and to
prevent serious personal injury, DO NOT attempt to
install the main cover on windy days.
1. Fasten a ratchet to the end conduit using a Tek screw
in the bottom hole of the ratchet as shown below.
NOTE:
Install the ratchet about 6" in from the end rafter
leg and through the installed end panel.
2. Repeat this step at all remaining corners.
3. Assemble two main cover conduits. Start each conduit
assembly with one (1) plain pipe and add swaged pipes
to arrive at the correct length.
NOTE:
Use duct tape to tape the Tek screws to prevent
damage to main cover.
Cover conduits are inserted into the pockets sealed
into the main cover. The conduits are used to tighten
and secure the main cover.
4. After assembling the cover conduits, locate the main
cover and unfold it on a clean, smooth surface near the
frame.
NOTE:
Unfold the main cover with the inside surface
facing up.
5. Locate the cover ends with strapping and align with the
front and back of the shelter.
6. Insert the cover conduits into the pockets of the main
cover.
Tek screw
Ratchet
6"