background image

1

CLEARSPAN

 END WALL FRAMING KITS

Revision date: 10.04.16

©2016 ClearSpan™

All Rights Reserved. Reproduction 

is prohibited without permission.

ClearSpan

 End Framing Kit 

26' Wide x 21'-9" High

Diagram shows the end framing kit with a single roll-up door.

STK#   

END FRAME KITS

115408 

Solid End Panel

115409 

14' x 14' Roll-Up Door

Содержание 115408

Страница 1: ... 2016 ClearSpan All Rights Reserved Reproduction is prohibited without permission ClearSpan End Framing Kit 26 Wide x 21 9 High Diagram shows the end framing kit with a single roll up door STK END FRAME KITS 115408 Solid End Panel 115409 14 x 14 Roll Up Door ...

Страница 2: ...ruction methods and techniques must seek the help of a qualified contractor ASSEMBLY PROCEDURE Following instructions as presented will help ensure proper assembly of end frame Steps outlining assembly are as follows 1 Verify all parts are included in the shipment Notify Customer Service for questions or concerns 2 Read these instructions the Must Read document and all additional documentation inc...

Страница 3: ...ll parts listed on Bill of Materials Spec Sheets are present If anything is missing or you have questions consult the Pictorial Parts Guide and all shelter diagrams for clarification or contact Customer Service NOTE At this time you do not need to open plastic bags containing smaller parts such as fasteners and clamps QUICK START GUIDE For a quick overview of the end frame and its components consu...

Страница 4: ... 10 04 16 The following graphics and photos will help identify the different parts Not all parts are shown FA4484B Tek Screw QH1330 Angled Bracket S350P024 3 50 x 3 50 Square Tube RVT40EWCS2 Square End Wall Cap Mounting Bracket Hex Cap Bolt and Nut ...

Страница 5: ...ed parts for each assembly procedure 2 Prepare and secure posts for the door framing See End Wall Diagrams in Quick Start Section 3 Assemble and attach all end framing Consult the Ratchet Relocation Diagram for additional information 4 Prepare and attach end panel if equipped ATTENTION View below shows end frame as seen standing outside a building looking at the end frame Rafter shown is not inclu...

Страница 6: ...ead end rafter and mark that location as well NOTE Mark center of end wall so multiple measurements can be made as needed 2 Using dimensions on End Frame diagrams locate positions of 4 x 4 vertical frame members for door framing 3 Dig a 12 diameter hole at the locations found in previous step to a depth that is below the geographic frost line 4 Add concrete to hole Concrete should remain 4 below g...

Страница 7: ...s and the 4 x 4 square tubing related hardware and connectors assemble door frame of end wall See Figure 1 above to properly position the Tek screws NOTE Consult the Exploded End Frame Diagram to properly position and connect brackets 2 Repeat steps to assemble remaining end framing using 1 50 x 1 50 square tubing and related connectors Use the FA4484B Tek screws to secure base rail to end frame a...

Страница 8: ...cover during stormy or windy conditions 3 Take a section of rope or strap long enough to reach over top chord of end rafter and tie it to center D ring of end panel This rope or strap is used to pull panel into position 4 With the 1 strapping in place loosen main cover bonnet if main cover is installed throw free end of strap over top of end rafter pull end panel into position and secure it to top...

Страница 9: ... if needed and tighten the 1 strap at end panel top NOTE Verify lower end of panel remains on ground as top is tightened In a later step end panel is stretched from the bottom to pull panel tight and into position using the end panel horizontal conduit straps and ratchets 7 With top edge of end panel secured to top chord of end rafter and panel evenly stretched continue with End Panel Conduit Inst...

Страница 10: ...h pipe joint with a Tek screw and wrap joint and screw with duct tape to prevent damage to end panel 3 Insert conduit into end panel horizontal pocket See diagrams for locations 4 Locate all QH1061 ratchets space them evenly along the inside of the bottom frame tube and attach these to frame tube using Tek screws Arrows in the following diagrams show where to attach ratchets Attach ratchets to the...

Страница 11: ...Opening procedure There are no vertical PVC conduits for an end panel that includes an overhead door END PANEL INSTALLATION CONTINUED End Frame and Panel No Overhead Door Install Vertical PVC End Panel Conduits If your end wall includes an overhead door skip this procedure and complete the Cut Door Opening procedure NOTE Attach PVC conduits to vertical frame members of the end wall using straps 1 ...

Страница 12: ...ed to keep panel from flapping during windy conditions 7 Cut if needed and tie remaining lower end of strap to end frame 8 Repeat steps to assemble and install remaining PVC conduit and strapping 10 After all conduit straps are tight move to top of end rafter and tuck end panel flap over top of end rafter at both ends End panel flap is tucked between rafter and main cover NOTE This flap can be sec...

Страница 13: ...reate and opening for the overhead door Step 3 Cut Horizontal Conduit used to stretch the end panel during installation END PANEL END PANEL 12 16 Horizontal Conduit Follow these steps to cut a door opening in the installed and stretched end panel 1 Consult diagram below and mark a 12 to 16 border on end panel within the door frame of end frame 2 Using the diagram and marks as guides remove end pan...

Страница 14: ...tracks and brackets View above shows back or inside surface of rafter as seen when standing inside assembled frame 2 After securing end panel to door frame install door according to instructions included with door NOTE If desired and depending on application bottom portion of end panel can be pulled under frame tube and secured to base tube as shown above Or as mentioned bottom edge of end panel c...

Страница 15: ...Check all fasteners frequently to verify these remain tight and in good repair Do not climb or stand on building or frame at anytime Remove debris and objects that may accumulate on shelter Use tools that will not damage cover when removing debris Remove snow to prevent excess accumulation Use tools that will not damage cover when removing snow Never allow snow to accumulate on main cover or remai...

Страница 16: ...FRAMING KITS 16 Revision date 10 04 16 QUICK START GUIDE 26 Wide End Frame Kit ATTENTION Kit shown above includes overhead door Actual kit may include end panel and end frame only Additional purchase required for door kit ...

Страница 17: ... page Hex Cap Bolts 1 0 4 2 6 0 1 0 4 2 6 0 Back View Front View Hex Cap Bolts FAG365B BASIC INSTALLATION STEPS 1 2 holes 1 Place the 105351 brackets on the 104260 header tube mark hole locations and drill 9 16 holes Do not attach at this time 2 Insert one RVT40EWCS2 into each S40P197G13 4 x 4 post 3 Move to the bottom of each S40P197G13 tube and drill two 1 2 mounting holes in center of each tube...

Страница 18: ...ubing is not pre drilled Field drill tubing during assembly Connections not shown are the same as Door End connections see previous page See previous end frame diagram to bolt 4 x 4 post to post set in concrete S350P024 S15P072 102897 between door jambs Secure splice using a Tek screw S40P197G13 S40P197G13 Hex Cap Bolts 1 2 x 5 1 2 ATTENTION Install two 2 Tek screws through backside of door jamb i...

Страница 19: ...PAN END WALL FRAMING KITS Revision date 10 04 16 FRONT PROFILE 14 0 x 14 0 DOOR OPENING INSIDE DIMENSIONS 104260 RVT40EWCS2 S40P197G13 S35P024 QH1330 S15P067 S15P067 QH1330 105351 105351 GROUND LEVEL 21 8 15 16 ...

Страница 20: ...6 CONNECTIONS WITH DOOR GROUND LEVEL VIEW 1 LOWER BEAM TO RAFTER CONNECTION VIEW 2 COLUMN TO LOWER BEAM CONNECTION VIEW 4 COLUMN TO HEADER CONNECTION VIEW 3 COLUMN TO RAFTER CONNECTION ATTENTION End wall as seen standing outside building looking at end wall ...

Страница 21: ...T S350P024 ANGLE BRACKET QH1330 4X 14 X 1 TEK SCREW 1 5 x 1 5 TUBING VIEW 2 COLUMN TO LOWER BEAM CONNECTION 4 x 4 HEADER 104260 MOUNTING BRACKET 105351 4X 1 2 X 5 1 2 HEX CAP 4X 1 2 HEX NUT 4 x 4 COLUMN S40P197G13 VIEW 4 COLUMN TO HEADER CONNECTION RAFTER END WALL CAP RVT40EWCS2 4 x 4 COLUMN S40P197G13 2X 3 8 X 3 1 2 HEX CAP 2X 3 8 HEX NUT VIEW 3 COLUMN TO RAFTER CONNECTION ATTENTION Details as se...

Страница 22: ...WALL FRAMING KITS 22 Revision date 10 04 16 14 0 x 14 0 DOOR OPENING INSIDE DIMENSIONS 21 8 15 16 GROUND LEVEL END PANEL DETAILS NOTE SOLID END WALL IS 115408 END WALL WITH 14 X 14 OPENING WITH ROLL UP DOOR IS 115409 ...

Страница 23: ...hese ratchets must be removed to install end panel After installing end panel reattach ratchets to end wall frame tube See diagrams below Frame shown may differ from actual frame Diagram above shows a typical ratchet setup for a building without an end wall Diagram above shows where to attach ratchet after end frame and end panel are installed Diagram above shows ratchet and main cover bonnet stra...

Отзывы: