39
H
IN FIELD OPERATION
OPERATORS MANUAL - HYBRID - M3, M4, M4R, M4.8 & M6
PRE-EMERGENCE MARKERS
Depending on your machines specifications pre-emergence markers may be fitted to your machine. This
optional extra allows tramline marks to be made visible behind the drill, therefore making it easier to apply
pre-emergence sprays. Images of the markers can be seen below.
1. Left hand pre-emergence marker
2. Right hand pre-emergence marker
The pre-emergence markers will be activated when the target tramline bout number is reached. If the
markers are not leaving enough of a visible mark during use then the aggressiveness of them can be altered.
This is achieved by slackening the retaining bolts and turning the stub axle to increase aggressiveness.
1. Slacken bolts to alter
marker
2. Marker stub axle
Once the points have become worn it may be advisable to extend the marker points using the extra holes.
This is accomplished by removing the two bolts, sliding the point further down the tine and reinserting the
bolts. This will ensure a clear mark is left behind the drill.
1. Bolts to remove in
order to extend
point
2. Marker point
1.
2.
1.
1.
1.
2.
2.
1.
1.
2.
Содержание HYBRID M3
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 14: ...E SAFETY 14 OPERATORS MANUAL HYBRID M3 M4 M4R M4 8 M6 Decal Location ...
Страница 15: ...15 E SAFETY OPERATORS MANUAL HYBRID M3 M4 M4R M4 8 M6 Decal Locations SAFETY DECALS IF BOUT MARKERS ARE FITTED ...
Страница 17: ...17 E SAFETY OPERATORS MANUAL HYBRID M3 M4 M4R M4 8 M6 Decal Location ONLY RELEVANT TO M3 AND M4R MACHINES ...
Страница 18: ...E SAFETY 18 OPERATORS MANUAL HYBRID M3 M4 M4R M4 8 M6 Decal Locations ONLY RELEVANT TO M3 AND M4R MACHINES ...
Страница 44: ...H IN FIELD OPERATION 44 OPERATORS MANUAL HYBRID M3 M4 M4R M4 8 M6 Seed Rate Calibration Chart M3 ...
Страница 45: ...45 H IN FIELD OPERATION OPERATORS MANUAL HYBRID M3 M4 M4R M4 8 M6 Seed Rate Calibration Chart M4 M4R ...
Страница 46: ...H IN FIELD OPERATION 46 OPERATORS MANUAL HYBRID M3 M4 M4R M4 8 M6 Seed Rate Calibration Chart M4 8 ...
Страница 47: ...47 H IN FIELD OPERATION OPERATORS MANUAL HYBRID M3 M4 M4R M4 8 M6 Seed Rate Calibration Chart M6 ...
Страница 65: ...65 I CARE AND MAINTENANCE OPERATORS MANUAL HYBRID M3 M4 M4R M4 8 M6 PAGE LEFT BLANK ...