91
SMARTFLOW II
How to Enter Calibration Mode (Cont.)
2. Allows user to view and change the cal factors.
To enter “View and Change” Calibration Mode:
• T
oggle the Spray Switch to
OFF.
• Turn Rotary switch to Target Rate” position.
Press and hold both the
CAL
and
INC
button
for 1 second. The work “
SET
" will be displayed
in the Data display window and the word “
CAL
”
will be displayed in the Application Rate dis-
play window. The red Warn
LED
will flash on/
off as a warning that the cal factors can be set
(changed). A calibration factor is selected with
the rotary switch. The word
“
SET
" remains in
the Data display window until the user releases
both the
CAL
and
INC
buttons to prevent ac-
cidental increments to a Cal factor. The
INC
or
DEC
buttons are used to adjust the Calibrate
factor and the longer the key is pressed the
faster the value will change.
To exit “View and Change” Calibration Mode:
• Press the
CAL
button for 1 second with the
rotary switch in any position. The Spray switch
can be in
VARIABLE
,
CONTINUOUS
or
OFF
.
If a Cal change was made the SmartFlow II
will store the Cal factors in
EEPROM
.
• To exit Calibration Mode without saving any
changes, simply turn the Power off.
SPRAY
VAR
CONT
OFF
TARGET
RATE
1 SEC
CAL
sET
+
+
-
CAL
CALIBRATION