65
SMARTFLOW II
Volume Counters
Three Volume counters are provided. When in the
VOLUME
position the selected counter is indicated
by the Number icon (1, 2, 3) in the Data display and
a different counter can be selected by using
INC
key.
(Note the
DEC
key is not used since that is used to
clear the counter in some models). Cycling power or
brown outs will not change the selection. The user
cannot change the Counter selection while in
CALIBRATE
or
SPECIAL CALIBRATE
but it
can
be changed while in Test Speed mode.
If a flow signal is present then Volume continues to
accumulate while in the
VARIABLE
,
CONTINUOUS
or
OFF
mode. All three Volume counters are always
active and will accumulate volume (not just the selected
or displayed counter).
Area and Volume counters are coupled together
(as pairs) so selecting Volume counter 1 also selects
Area Counter 1. This was done so user can easily see
how much Volume was applied to a particular area
(Volume 1 is always applied to Area 1, and Volume 2
to Area 2 etc.).
Area Counters
Three Area counters are provided. When in the
AREA
position the selected counter is indicated by the Num-
ber icon (1, 2, 3) shown in the Data display and a differ-
ent counter can be selected by using the
INC
key.
Cycling power or brown outs will not change the
selection. The user can not change the Counter
selection while in
CALIBRATE
or
SPECIAL CALIBRATE
but it can be changed while in Test Speed mode.
Area is only accumulated while in the
VARIABLE
mode
(and not “Lo Speed” or “Hi Speed”) and all three
counters are active and will accumulate area (not just
the selected or displayed counter). When in the
CONTINUOUS
or
OFF
mode all three Area counters
stop accumulating area.
Area and Volume counters are coupled together
(as pairs) so selecting Area counter I also selects Volume
Counter 1. This was done so the user can easily see how
much Volume was applied to a particular area (Volume 1
is always applied to Area 1, and Volume 2 to Area 2 etc.).
The Speed Cal factor can be changed at any time
(before or after a field is completed) and the correct
area will be re-computed.
Volume Counters
Area Counters
NOTE:
The DEC key is not used since that is
used to clear the counter in some models:
‘Lite’ and ‘D’.
TOTAL COUNTERS
Содержание PRO-MIST DURA
Страница 1: ...INSTRUCTION MANUAL AND PARTS LIST PRO MIST DURA WITH SMARTFLOW II ...
Страница 11: ...8 PRO MIST DURA ULV Mount to Vehicle Cont 3B 4B 5B INSTALLATION ...
Страница 42: ...39 PRO MIST DURA ULV Pump Electrical Cabinet PARTS BOOK AND COMPONENTS ...
Страница 62: ...SMARTFLOW II INSTRUCTION MANUAL ...