Wheel System, Traction
62
Service Manual – CA90 32T
Shop Measurements
Measurement at Pin
Circumstances
Voltmeter Reading
Curtis Controller Pin 18
Trigger On
4.5 volts DC
Trigger Off
.7 volts DC
Curtis Controller Pin 17
Reverse On & Trigger On
37.1 volts DC
Reverse Off or Trigger Off
0 volts DC
Curtis Controller Pin 13
Any
.42 volts DC
Curtis Controller Pin 5
Key On & Trigger On
37 volts DC
Curtis Controller Pin 4
Trigger On with Speed pot. at
minimum
4.6 volts DC
Trigger On with Speed pot. at
maximum
.43 volts DC
Curtis Controller Pin 3
Trigger On
4.5 volts DC
Trigger Off
.7 volts DC
Curtis Controller M1 to M2 with
transaxle unplugged
Trigger On, Forward, at
Maximum Speed
26.6 volts DC
Trigger On, Reverse, at Maximum
Speed
- 13.9 volts DC
Transaxle amp draw
Maximum Speed
1.9 amperes