Trigger Switch
1. Disconnect the batteries.
2. Remove the (4) screws from the upper control housing panel (dash board), and the (4) screws from the
lower control housing panel.
3. GENTLY move them aside to gain access to the inside of the control housing. (See picture above)
4. Use a needle nose pliers (needle nose vice grips work the best) to hold the nylock nut on top of the
switch. Reach up with a #1 phillips screwdriver to unscrew the screw. Repeat this for the other nut and
screw. NOTE: The 3 mm screws strip easily, so be careful.
5. Swing the switch with wires still connected into a position where you can dis-connect/re-connect the
wires from the switch.
6. Note that the switch information printed on the switch is away from you (facing down).
7. One at a time, dis-connect the wires from the old switch and re-connect them to the new switch.
8. Reinstall the switch in the reverse order of the steps above.