Solution System
47
Service Manual – CA90 32T
Maintenance and Adjustment
Solution Filter Cleaning
1.
Work near a floor drain for convenient clean up if possible.
2. Turn the key switch OFF.
3. Close the Solution shut-off valve (The valve is closed when the handle is NOT in line with the hose)
4.
Unscrew the solution filter cover
5. Remove and clean the screen.
6.
Re-assemble in the reverse order. Make sure the gasket is seated properly in the filter cover.
7. Open the shut-off valve, and check for leaks.
Resetting the Solution Flow Adjustment Knob
NOTE: The solution valve has approximately (5) full 360 degree turns of adjustment from OFF to Maximum.
The solution flow adjustment knob allows only about (1) full turn of adjustment. The factory setting is at the
mid-range of the solution valve. Some customers want more solution flow (i.e. for unfinished concrete floors),
while some customers may want less solution flow (i.e. for VCT)
1. Use a pliers to grip the brass knob stop.
2. Use a #2 phillips screwdriver to remove the screw that holds the pin. (Directly under the pin)
3.
Turn the solution adjustment flow knob to get the desired amount of solution flow. Clockwise for LESS
flow, Counter-clockwise for MORE solution flow. NOTE: Do not adjust the knob too far. If you adjust
the knob to the Minimum or Maximum position of the solution valve, it can get stuck.
4. Replace the brass knob stop.
Содержание CA90 32T
Страница 1: ...Clarke CA90 32T 11 2015 Form No 56043170 Service Manual Model Numbers Clarke 810T English...
Страница 24: ...Recovery System 24 Service Manual Machine Name Vacuum Solenoid Vacuum Circuit Breaker Ball Float Assembly...
Страница 28: ...Recovery System 28 Service Manual CA90 32T...
Страница 46: ...Solution System 46 Service Manual Machine Name Solution Valve Solution Switch Solution Flow Adjustment Knob...
Страница 55: ...Wheel System Traction 55 Service Manual CA90 32T Transaxle Transaxle Motor MAIN Solenoid...