9. Now you can pull the valve out a bit to access the allen screw that attaches the adjust cable to the
adjustment shaft of the valve.
10. Loosen the allen screw, and disconnect the cable from the valve.
11. Remove the (2) green wires. Note which wire goes to which tab on the valve.
12. Rotate the adjustment shaft of the new valve so that it is approximately in the same setting as the old
valve.
13.
Insure the Jam nut on the valve is not tightened.
14.
Install the new valve in the reverse order of the above steps.
Specifications
The maximum flow rate of the solution system is 1 gallon per minute maximum. This is under ideal
conditions with a full solution tank, and all new components. The flow rate is infinitely adjustable to zero
flow rate from there.