Scrub System
41
Service Manual – CA90 32T
•
Dis-connect the motor connector. (NOTE - There may be protective heat shrink over the connector. If so,
carefully cut away the heat shrink))
•
Lift the motor out.
Installation
•
Set the new motor in approximately the same location as the motor removed. (NOTE: This should be
fairly easy to see due to the dirt build-up around the mounting bolts)
•
Install and tighten the (4) mounting bolts/lockwashers.
•
Re-install the drive plate assembly;
–
Place the shaft key in the slot in the drive plate. Hold it in place with your finger, and rotate the drive
plate so that the key lines up with the slot in the motor shaft.
–
Slide the drive plate fully onto the shaft. (NOTE: You may have to wiggle the drive plate)
–
Re-attach the drive plate with the bolt and thick washer. (NOTE: Use RED Loctite on the drive plate
bolt)
•
Re-connect the brush motor connector.
•
Re-connect the batteries, and turn the key to ON. Insure the speed control is set to minimum, turn on
the brush switch and pull the trigger to turn on the brush motor. Make sure the brush is rotating in the
correct direction. (Right motor goes counter-clockwise, Left motor goes clockwise.
–
If the brush is not rotating in the correct direction, you will need to swap the position of the wires in
the brush motor connector.
•
Apply heat shrink to protect the connector.
•
Wire tie all of the connectors so they cannot contact the linear actuator.
•
Re-install the front cover.
Linear Actuator
Removal:
•
Completely drain the recovery tank.
•
Lift the recovery tank, and secure the tank support latch.
•
Remove the front cover of the machine by removing the (4) knobs.
•
With the machine key in the ON position, lower the brush deck so it’s resting on the floor using the
actuator switch.
NOTE - If the Linear Actuator is not functioning, you may have to prop the brush deck up with
blocks to remove the actuator.
•
Turn the key to the OFF position, and disconnect the batteries.
• Straighten the cotter pin that secures the upper mounting pin
Содержание CA90 32T
Страница 1: ...Clarke CA90 32T 11 2015 Form No 56043170 Service Manual Model Numbers Clarke 810T English...
Страница 24: ...Recovery System 24 Service Manual Machine Name Vacuum Solenoid Vacuum Circuit Breaker Ball Float Assembly...
Страница 28: ...Recovery System 28 Service Manual CA90 32T...
Страница 46: ...Solution System 46 Service Manual Machine Name Solution Valve Solution Switch Solution Flow Adjustment Knob...
Страница 55: ...Wheel System Traction 55 Service Manual CA90 32T Transaxle Transaxle Motor MAIN Solenoid...