Scrub System
39
Service Manual – CA90 32T
•
Re-assemble the motor to the gearbox. There are timing marks on the case, and the aluminum ends.
Make sure these are aligned.
•
Re-install the (2) motor screws. NOTE: The magnets inside the case will try to pull these inward.
•
Re-connect the brush motor connector, tie wrap the brush connectors back together.
•
Re-install the front shroud.
Troubleshooting
Problem
Causes
Solution
Neither brush Motor will run
Defective Brush Switch
Replace Brush switch
Defective Trigger
Switch
Replace Trigger Switch
Defective Brush Solenoid
Replace Brush Solenoid
Wiring issue
Trace wiring per diagram
Only one brush will run, or
one brush runs slowly
Circuit breaker tripped
Reset Circuit breaker
Carbon Brushes
in brush motor are
defective
Replace carbon brushes
Brush motor defective
Replace Brush motor