Recovery System
30
Service Manual – CA90 32T
Removal and Installation
Vacuum motor
Removal:
•
Completely drain the recovery tank
•
Turn the keyswitch to OFF.
•
Lift the left side of the recovery tank, and insure the recovery tank support bracket latches into place.
•
Disconnect the battery connector.
•
Disconnect the vacuum motor wire connector (NOTE: There may be protective heat shrink covering the
connector. If so, carefully cut the heat shrink away.)
•
Remove the (3) 10mm nylock nuts that hold the vacuum motor to the mounting studs. (NOTE: You may
have to hold the studs to prevent them from turning)
•
Slide the vacuum motor past the mounting studs and out.
Installation:
•
Install a new vacuum motor gasket onto the new vacuum motor.
•
Slide the new vacuum motor over the mounting studs. (NOTE: The vacuum motor must be installed in
the correct orientation)