Scrub System
37
Service Manual – CA90 32T
Replacement of Carbon Brushes
•
Turn the machine key switch to OFF.
•
Dis-connect the batteries from the machine.
•
Remove the front shroud to access the brush motors.
•
Remove the wire ties, and dis-connect the brush motor connectors.
•
Remove the (2) motor bolts.
•
Wiggle the motor back and forth to release the motor from the gearbox.
•
Place the motor on the floor upside down, and slide a straight screwdriver between the top motor cover
and the motor case. Place your foot on the screwdriver to hold the cover down. Lift off the case. NOTE:
You must overcome the force of the magnets in the case.
Motor bolts x 2
Содержание CA90 32T
Страница 1: ...Clarke CA90 32T 11 2015 Form No 56043170 Service Manual Model Numbers Clarke 810T English...
Страница 24: ...Recovery System 24 Service Manual Machine Name Vacuum Solenoid Vacuum Circuit Breaker Ball Float Assembly...
Страница 28: ...Recovery System 28 Service Manual CA90 32T...
Страница 46: ...Solution System 46 Service Manual Machine Name Solution Valve Solution Switch Solution Flow Adjustment Knob...
Страница 55: ...Wheel System Traction 55 Service Manual CA90 32T Transaxle Transaxle Motor MAIN Solenoid...