Scrub System
43
Service Manual – CA90 32T
•
Place the tube portion of the actuator into the spring bracket so the holes line up.
•
Insert the lower mounting pin, and secure it with the hairpin.
•
Position the upper end of the actuator into the actuator bracket.
• Insert the upper mounting pin,
•
Reconnect the actuator wires. (RED to wire 17, Black to wire 18)
•
Wire tie all of the connectors so they cannot contact the linear actuator.
•
Re-install the front cover.
Component Specifications (electrical)
Component
Specifications
Scrub Deck Motor
RPM – 200
Current Draw – No Load - 3 Amps
Current Draw - Full Load - 6 - 8 Amps depending on floor
conditions
Scrub Deck Actuator
Total Travel – 4.00” ±0.15”
Performance Data
No load
Current Draw – 1.8 ±1.0 Amps max.
Full load
Current Draw – 3.0 ±1.0 Amps