Remove bottom panel for performing weekly cleaning, in order to get access to the bottom of
the basin.
Do the following:
1.
Remove containers or trays with displayed product from the cabinet.
2.
Turn off the cabinet and disconnect it completely from the electrical net.
WARNING:
Before performing any weekly cleaning operation, be sure that the cabinet is turned off and
completely disconnected from electrical net.
3.
Remove internal movable panels. Clean the with care using neutral cleaners; wash them with
water and dry using a soft cloth.
WARNING:
Removing bottom panels you will get free access to the evaporators surfaces which are
sharp and could injury the staff: wear always suitable gloves when performing weekly
cleaning.
4.
Use a humid sponge to remove any residual of displayed product and dirt from the basin.
Avoid using too much water that could damage electric components.
WARNING:
Don’t tamper or damage electrical connections and wires or the refrigerating system piping,
inside and below the basin.
5.
Clean the basin with a dry cloth and let it dry completely.
6.
Put all the bottom panels back in place as they where positioned before.
7.
Turn on the cabinet again.
WARNING:
Use of abrasive, corrosive products, solvents , acids that could cause irreparable damages
on surface and start corrosion must be avoided.
Don’t pour flammable products on hot parts such as lamps, LEDs, ballasts and so on.
Don’t pour water on electric components such as fan motors, lights and so on..
WARNING:
In case of Electric water-evaporating pans optional don’t use too much water during
cleaning operations in order to avoid water spillage on floor.
WARNING:
During cleaning operations of movable glasses, be careful in opening and closing the glass,
accompanying it until its final position. Avoid to lean on the open glass during cleaning
phases.
5.3
P
ROGRAMMED
M
AINTENANCE
–
C
ONDENSER
C
LEANING
Содержание Gemma J G12
Страница 1: ......
Страница 8: ...Gemma J Ice Cream Cabinet English pag 8 2 3 TECHNICAL DRAWING CUSTOMER SIDE OPERATOR SIDE...
Страница 31: ...Gemma J Ice Cream Cabinet English pag 31 Version 400 3 50 Semi hermetic compressor...
Страница 33: ...Gemma J Ice Cream Cabinet English pag 33 Version 400 3 50 Semi hermetic compressor...
Страница 35: ...Gemma J Ice Cream Cabinet English pag 35 Version 400 3 50 Semi hermetic compressor...
Страница 36: ...Gemma J Ice Cream Cabinet English pag 36 7 4 LOAD AND LIGHT CONNECTIONS Version 230 1 50...
Страница 41: ...Gemma J Ice Cream Cabinet English pag 41 8 3 COOLING SYSTEM W CONDENSING UNIT TWIN COMPRESSOR SYSTEM...
Страница 43: ......