Clabo Gemma J G12 Скачать руководство пользователя страница 13

 

 

Gemma J 

Ice Cream Cabinet

 

 

English

  

  

 

pag. 13 

 

 

3-phases power supply 

The display cabinet is supplied with a 5-wire cable; 

 

Yellow/Green = Grounding wire 

 

Blue = Neutral Line 

 

Brown = Live n.1 (phase) 

 

Grey = Live n.2 (phase) 

 

Black = Live n,3 (phase) 

 

 

WARNING:  

Never cut or remove the yellow-green cable mentioned above: 

risk of Electrical Shock

 

 

The supply cables must be connected to the main network, which must be equipped with an 

efficient  earthing  network,  in  accordance  with  the  national  and  local  norms  (where  existent)  for 
electrical installations and they must be suitable for the electrical absorption of the display cabinet. 
Please refer to the table in correspondent chapter of the present manual, absorption column. 
 

Please  ensure  that  means  for  disconnection  must  be  incorporated  in  the  fixed  wiring  in 

accordance with the wiring rules. 

 

 

WARNING:  

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 
similarly qualified person in order to avid a hazard. 

 

WARNING:  

The  electrical  connection  to  the  network  must  be  carried  out  by  means  of  the  three  wires 
included, the central plant to which the cabinet is connected must also have a switch with 
contact openings measuring at least 3mm and protected by fuses. 

 

WARNING:  

Apply  an  adequate  anchoring  method  to  the  supply  cable  in  the  connection  box,  making 
reference to the table outlined below. 

 
 

NOMINAL CURRENT 

[A] 

NOMINAL SECTION [mm

2

]

 

FLEXIBLE CABLES 

[mm

2

CABLES FOR EARTHING 

[mm

2

0,5  ÷  0,75 

1   ÷  2,5 

3 ÷ 6 

0,75  ÷  1 

1  ÷  2,5 

6 ÷ 10 

1  ÷  1,5 

1  ÷  2,5 

10 ÷ 16 

1,5  ÷  2,5 

1,5  ÷  4 

16 ÷ 25 

2,5  ÷  4 

2,5  ÷  6 

25 ÷ 32 

4  ÷  6 

4  ÷  10 

32 ÷ 40 

6  ÷  10 

6  ÷  16 

40 ÷ 63 

10  ÷  16 

10  ÷  25 

Содержание Gemma J G12

Страница 1: ......

Страница 2: ...ng Connections 12 3 6 Electrical Connections 12 3 7 Water Drainage 14 3 8 End of Service and Disposal 14 4 Functioning 15 4 1 General Use Rules 15 4 2 Start Up 16 4 3 Control Board EWPlus 974 RTC OPTI...

Страница 3: ...aintenance Condenser Cleaning 25 5 4 Summary of Scheduled Maintenance 26 6 Practical Troubleshooting Guide 27 7 Electrical Drawings standard version 30 7 1 Electrical Diagram Gemma J G6 G9 G12 EWplus...

Страница 4: ...manual must be kept in good conditions and follow the cabinet during its entire operative life until dismissing in order to have all the information needed for maintenance of the qualitative and safet...

Страница 5: ...ing technical assistance try to fix the problem following the troubleshooting guide reported in the chapter n 6 If the problem cannot be fixed using the troubleshooting guide contact the authorized te...

Страница 6: ...hases power supply Cooling System is equipped with Semi hermetic compressor condensing unit is installed on the machine in a compartment of the base The machine has an automatic defrosting cycle regul...

Страница 7: ...ATA Weight Kg Working Temp C Gas Electrical Supply Total Absorbed Power W Cooling Capacity W G6 230V 230 18 20 R404a 230 1 50 1800 889 G9 230V 340 18 20 R404a 230 1 50 2200 1200 G12 230V 450 18 20 R40...

Страница 8: ...Gemma J Ice Cream Cabinet English pag 8 2 3 TECHNICAL DRAWING CUSTOMER SIDE OPERATOR SIDE...

Страница 9: ...of Remote Condensing Units where available must be performed by qualified personnel following the instruction reported on manual delivered with the condensing unit itself and supplied by the factory 3...

Страница 10: ...icient space for use and maintenance in conditions of safety as foreseen by the UNI EN 12100 2010 Ensure the existence of a suitable earthing plant as foreseen by the European Norms Once the cabinet i...

Страница 11: ...any hot air sources the display cabinet is not exposed to direct sunlight the cooling air grills of the condenser are not blocked fig 7 pos A air conditioning or heating in the room are not directed...

Страница 12: ...uldn t exceed 20 C in order not to decrease machine s performances 3 6 ELECTRICAL CONNECTIONS Before installation check that a suitable earth plant is present as envisioned by the regulations in force...

Страница 13: ...on column Please ensure that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules WARNING If the supply cord is damaged it must be replaced by the manuf...

Страница 14: ...untry of use End of service of display cabinet When the display cabinet has reached the end of its life span Remove the refrigerant from the refrigerator circuit of the display cabinet Empty it of all...

Страница 15: ...n using suitable alimentary containers If the displayed products exits from their containers this cannot be sold or used it must be removed and wasted WARNING To prevent the deviation of the air flow...

Страница 16: ...ind the back protection board Remove the fixing screws from the back board as shown in Picture 9 position B and set the main switch on the 1 position picture 9 position A by activating the showcase s...

Страница 17: ...rm condition does not exist the display will visualize the label SEt Press the keys or for going through the other labels AL alarm folder SEt Set point temperature folder rtC Clock Parameters o dAy da...

Страница 18: ...ot exist the display will flash 3 times indicating the failure of defrost cycle start 4 8 STAND BY FUNCTION OPT A Keep pressed the ESC button for entering on Stand By Mode the display will visualize O...

Страница 19: ...ed for 3 seconds to start the manual defrosting cycle Use this button to turn the display cabinet lights on and off Turn the cooling system on off Keys Combinations Press and hold together for three s...

Страница 20: ...led starts to flash Modify the value using and keys Memorize the new set value pressing again SET button The value will flash Wait at least 15 seconds to exit from setpoint programming mode Press and...

Страница 21: ...min stored temperature in programming mode it browses the parameter codes or decreases the displayed value To switch the instrument off if onF oFF Not enabled KEY COMBINATIONS To lock unlock the keybo...

Страница 22: ...again or by wayting 5s the normal display will be restored How to reset the MAX and MIN temperature recorded 1 Hold press the SET key for more than 3s while the max or min temperature is displayed rSt...

Страница 23: ...ing 2 Select the required parameter Press the SET key to display its value 3 Use and to change its value 4 Press SET to store the new value and move to the following parameter To Exit Press or wait 15...

Страница 24: ...le contacts between the displayed products and not alimentary chemicals the product should be removed and wasted it can t be used or sold Glass surfaces Clean glass surfaces back door front and side g...

Страница 25: ...Avoid using too much water that could damage electric components WARNING Don t tamper or damage electrical connections and wires or the refrigerating system piping inside and below the basin 5 Clean t...

Страница 26: ...al net 2 Remove the back protection grid 3 Remove dust and dirt present on the condenser fins using a brush or a vacuum cleaner fig 10 5 4 SUMMARY OF SCHEDULED MAINTENANCE Ordinary Maintenance Generic...

Страница 27: ...t the intervention of the assistance service for the replacement of the same The display cabinet is exposed to air currents or direct sunlight The display cabinet does not function in these conditions...

Страница 28: ...y level 3 The compressor never stops or it works for very long periods of time Probable Cause Probable Solution The room temperature is very high e g above 32 C If it is not possible to lower the room...

Страница 29: ...Probable Solution The light switch is not turned on Turn on the light switch The LED bars are not connected properly Verify that the 4 pin connector between two LED bars is inserted properly The LED b...

Страница 30: ...Gemma J Ice Cream Cabinet English pag 30 7 ELECTRICAL DRAWINGS STANDARD VERSION 7 1 ELECTRICAL DIAGRAM GEMMA J G6 G9 G12 EWPLUS 974 RTC Version 230 1 50 Hermetic compressor...

Страница 31: ...Gemma J Ice Cream Cabinet English pag 31 Version 400 3 50 Semi hermetic compressor...

Страница 32: ...Gemma J Ice Cream Cabinet English pag 32 7 2 ELECTRICAL DIAGRAM GEMMA J G6 G9 G12 T640 KEYBOARD Version 230 1 50 Hermetic compressor...

Страница 33: ...Gemma J Ice Cream Cabinet English pag 33 Version 400 3 50 Semi hermetic compressor...

Страница 34: ...Gemma J Ice Cream Cabinet English pag 34 7 3 ELECTRICAL DIAGRAM GEMMA J G6 G9 G12 XR60CX Version 230 1 50 Hermetic compressor...

Страница 35: ...Gemma J Ice Cream Cabinet English pag 35 Version 400 3 50 Semi hermetic compressor...

Страница 36: ...Gemma J Ice Cream Cabinet English pag 36 7 4 LOAD AND LIGHT CONNECTIONS Version 230 1 50...

Страница 37: ...Gemma J Ice Cream Cabinet English pag 37 7 5 CONDENSING UNIT CONNECTION BOX HERMETIC COMPRESSOR SUPPLY 50 HZ Version 230 1 50...

Страница 38: ...Gemma J Ice Cream Cabinet English pag 38 7 6 CONDENSING UNIT CONNECTION BOX SEMI HERMETIC COMPRESSOR SUPPLY 50 HZ Version 400 3 50...

Страница 39: ...Gemma J Ice Cream Cabinet English pag 39 8 COOLING SYSTEMS DIAGRAMS 8 1 COOLING SYSTEM W CYCLE INVERSION DEFROST G6 G9 G12...

Страница 40: ...Gemma J Ice Cream Cabinet English pag 40 8 2 CONDENSING UNIT SCHEME 1 HERMETIC COMPRESSOR UNITA REFRIGERANTE 1 2 3 4 5 6 7 8...

Страница 41: ...Gemma J Ice Cream Cabinet English pag 41 8 3 COOLING SYSTEM W CONDENSING UNIT TWIN COMPRESSOR SYSTEM...

Страница 42: ...in garanzia o dei componenti difettosi sostituiti da rendere a Clabo Spa sono a carico del cliente WARRANTY TERMS Clabo Spa undertakes to provide warranty on its products to the first purchaser of the...

Страница 43: ......

Отзывы: