ci5000 Series Printer Technical Service Manual
Version 0.1
6-32
3. Check Pressure Transducer (possibly an incorrect reading).
See “
Pressure Sensor Inaccurate
”
Pump Pressure Error
–
PRESSURE LOW
Definition:
This error/fault is caused when the pressure is continually falls below the set point (usually this is 40psi).
Corrective Action:
1. The Filter Module is clogged or dirty. Ensure that Filters have been changed within the timeframe
specified in the maintenance chart.
2. Ink Pickup Tube is too close to Return Tubes. Ensure the Pickup Tube is set to the center of the
ink tank and the return tubes are pointing away as seen in the picture below.
3. Ensure the Pickup Tube does not have anything blocking the input flow.
Содержание ci5200
Страница 2: ...ci5000 Series Printer Technical Service Manual Version 0 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 33: ...ci5000 Series Printer Technical Service Manual Version 0 1 1 27 Alignment Quick release buttons 1 2 1 2 ...
Страница 34: ...ci5000 Series Printer Technical Service Manual Version 0 1 1 28 Ink System Diagram ...
Страница 47: ...ci5000 Series Printer Technical Service Manual Version 0 1 2 10 ...
Страница 129: ...ci5000 Series Printer Technical Service Manual Version 0 1 4 6 Encoder ...
Страница 130: ...ci5000 Series Printer Technical Service Manual Version 0 1 4 7 Beacon Options ...
Страница 132: ...ci5000 Series Printer Technical Service Manual Version 0 1 4 9 ...
Страница 172: ...ci5000 Series Printer Technical Service Manual Version 0 1 6 28 Fig 1 Fig 2 High Voltage Trip Definition ...
Страница 189: ...ci5000 Series Printer Technical Service Manual Version 0 1 6 45 Pic 3 Pic 4 Ink Reservoir Low ...
Страница 222: ...ci5000 Series Printer Technical Service Manual Version 0 1 6 78 ...
Страница 285: ...ci5000 Series Printer Technical Service Manual Version 0 1 11 4 Schematics Display Touch Connections ...
Страница 286: ...ci5000 Series Printer Technical Service Manual Version 0 1 11 5 Electrical Connections ...
Страница 287: ...ci5000 Series Printer Technical Service Manual Version 0 1 11 6 Fluids Connections ...