Three fan modules (2 used
for operations and one
used for redundancy) of
the following types:
Fan slots are numbered 1
(leftmost slot) to 3
(rightmost slot).
4
You can use the 1- and 10-Gigabit ports to connect this switch to up to 48 devices or to FEXs, which can be
connected to additional servers (for the number of FEXs that can be supported, see the release notes for the
NX-OS software that you are using). You can connect any of the supported FEXs to the downlink ports.
For installation information on the Cisco Nexus 2000 Series FEXs, see the
Cisco Nexus 2000 Series Hardware
Installation Guide
. For information on a B22-HP FEX, see the Getting Started Guide for that FEX model.
Depending on whether you plan to position the ports in a hot or cold aisle, you can order the fan and power
supply modules with port-side intake or port-side exhaust airflow. For port-side intake airflow, the fan and
AC power supply modules have burgundy coloring (DC power supply modules have green coloring). For
port-side exhaust airflow, the fan and AC power supplies have blue coloring (DC power supply modules have
gray coloring).
The fan and power supply modules are field replaceable and you can replace one fan module or one power
supply module during operations so long as the other modules are installed and operating. If you have only
one power supply installed, you can install the replacement power supply in the open slot before removing
the original power supply.
All of the fan and power supply modules must have the same direction of airflow. Otherwise, the switch can
overheat and shut down. If you are installing a dual-direction power supply, that module will automatically
use the same airflow direction as the other modules in the switch.
Note
If the switch has port-side intake airflow (burgundy coloring for fan modules), you must locate the ports in
the cold aisle. If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the
ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down.
Caution
Cisco Nexus 9396PX ACI-Mode Switch Hardware Installation Guide
4
Overview
Overview
Содержание Nexus 9396PX
Страница 22: ...Cisco Nexus 9396PX ACI Mode Switch Hardware Installation Guide 12 Preparing the Site Clearance Requirements ...
Страница 64: ...Cisco Nexus 9396PX ACI Mode Switch Hardware Installation Guide 54 System Specifications System Specifications ...
Страница 68: ...Cisco Nexus 9396PX ACI Mode Switch Hardware Installation Guide 58 LEDs Power Supply LEDs ...