6-111
Cisco Unified Communications Manager Managed Services Guide
OL-22523-01
Chapter 6 Cisco Unified Serviceability Alarms and CiscoLog Messages
Error-Level Alarms
Facility/Sub-Facility
CCM_TFTP-TFTP
Cisco Unified Serviceability Alarm Definition Catalog
System/TFTP
Severity
Error (3)
Recommended Action
In Cisco Unified Serviceability, enable Detailed level traces in the Trace Configuration window for
TFTP service. Also, use RTMT to look for errors that may have occurred around the time of the alarm.
ConflictingDataIE
A call has been rejected because the incoming PRI/BRI Setup message had an invalid IE.
A call has been rejected because an incoming PRI/BRI Setup message contained an invalid Coding
Standard value in the Bearer Capability information element (IE). Unified CM only accepts PRI/BRI
Setup messages with Coding Standard values of 0 or 1. When an invalid IE is received, Unified CM
rejects the call setup and issues this alarm.
Cisco Unified Serviceability Alarm Definition Catalog
CallManager/CallManager
Severity
ERROR
Routing List
SDL
SDI
Sys Log
Event Log
Parameter(s
Device Name(String)
Recommended Action
Notify the service provider responsible for sending the Setup message that an IE with Coding Standard
values of 0 or 1 must be included in Setup messages.
ConnectionFailure
Cisco CallManager failed to open TLS connection for the indicated device. Possible reasons could be
wrong "Device Security Mode" configured, wrong "X.509 Subject Name" configured or unsupported
cipher algorithm.