24-22
User Guide for Cisco Security MARS Local Controller
78-17020-01
Chapter 24 System Maintenance
Hardware Maintenance Tasks—MARS 100, 100E, 200, GCM, and GC
Tip
Within the RAID utility, you can use the following keystrokes to highlight the corresponding
GUI button:
Alt-C—Create Array
Alt-D—Delete Array
Alt-M—Maintain Array
Alt-R—Rebuild Array
Step 6
Press
Y
to confirm. MARS exits the RAID utility and resumes the bootup process.
Step 7
At the CLI prompt, verify with the
raidstatus
command that the RAID array subunit is rebuilding.
If the subunit does not rebuild within two hours, delete the array and add the replacement drive with the
RAID utility as described in the section “
Add a Replacement Drive to the Array with the RAID Utility
.”
This ends the
Rebuilding an Array with the RAID Utility
procedure.
Add a Replacement Drive to the Array with the RAID Utility
This section pertains only to the MARS 100, 100E, 200, GCM, and GC appliances.
Perform this procedure when a hotswap attempt and the RAID Utility Rebuild procedure have failed.
Step 1
Insert the replacement drive into the hard drive slot.
Step 2
Establish a direct console connection to MARS with a keyboard and an external monitor.
Note
You can access the RAID Utility only with a direct console connection.
Step 3
Reboot the MARS Appliance. Press
Alt-3
to access the RAID utility when the following message
appears:
*** <Press Alt-3 to access 3ware Configuration Screen ***>
The 3ware Disk Array Configuration utility (RAID Utility) home screen appears.
Step 4
Read the help bar at the bottom of the screen for instructions on how to use the RAID Utility interface.
Step 5
Select
Array Unit 0
—position the cursor over the text and press Enter.
A selected item is marked with an asterisk in the leftmost column.
Step 6
Select
Delete Array
, and press Enter.
A screen appears listing the ports and the hard drives of the array that will be deleted.
Tip
Within the RAID utility, you can use the following keystrokes to highlight the corresponding
GUI button:
Alt-C—Create Array
Alt-D—Delete Array
Alt-M—Maintain Array
Alt-R—Rebuild Array
Содержание CS-MARS-20-K9 - Security MARS 20
Страница 20: ...Contents xx User Guide for Cisco Security MARS Local Controller 78 17020 01 ...
Страница 356: ...17 16 User Guide for Cisco Security MARS Local Controller 78 17020 01 Chapter 17 Network Summary Summary Page ...
Страница 420: ...20 28 User Guide for Cisco Security MARS Local Controller 78 17020 01 Chapter 20 Queries and Reports Reports ...
Страница 580: ...Glossary GL 4 User Guide for Cisco Security MARS Local Controller 78 17020 01 ...