![Cisco Catalyst 2350 Скачать руководство пользователя страница 87](http://html.mh-extra.com/html/cisco/catalyst-2350/catalyst-2350_command-reference-manual_67583087.webp)
2-63
Catalyst 2350 Switch Command Reference
OL-19055-01
Chapter 2 Catalyst 2350 Switch Cisco IOS Commands
errdisable recovery
Command Modes
Global configuration
Command History
Usage Guidelines
A cause (
all
,
bpduguard
, and so forth) is defined as the reason that the error-disabled state occurred.
When a cause is detected on an interface, the interface is placed in the error-disabled state, an operational
state similar to link-down state.
When a port is error-disabled, it is effectively shut down, and no traffic is sent or received on the port. For the
BPDU guard and port-security features, you can configure the switch to shut down just the offending
VLAN on the port when a violation occurs, instead of shutting down the entire port.
If you do not enable the recovery for the cause, the interface stays in the error-disabled state until you
enter the
shutdown
and the
no shutdown
interface configuration commands. If you enable the recovery
for a cause, the interface is brought out of the error-disabled state and allowed to retry the operation again
when all the causes have timed out.
Otherwise, you must enter the
shutdown
and then the
no shutdown
commands to manually recover an
interface from the error-disabled state.
Examples
This example shows how to enable the recovery timer for the BPDU guard error-disabled cause:
Switch(config)#
errdisable recovery cause bpduguard
This example shows how to set the timer to 500 seconds:
Switch(config)#
errdisable recovery interval 500
You can verify your settings by entering the
show errdisable recovery
privileged EXEC command.
Related Commands
Release
Modification
12.246)EY
This command was introduced.
Command
Description
show errdisable recovery
Displays error-disabled recovery timer information.
show interfaces
status
err-disabled
Displays interface status or a list of interfaces in error-disabled
state.
clear errdisable interface
Clears the error-disabled state from a port or VLAN that was error
disabled by the per-VLAN error disable feature.
Содержание Catalyst 2350
Страница 14: ...Contents xiv Catalyst 2350 Switch Command Reference OL 19055 01 ...
Страница 18: ...xviii Catalyst 2350 Switch Command Reference OL 19055 01 Preface ...
Страница 606: ...B 66 Catalyst 2350 Switch Command Reference OL 19055 01 Appendix B Catalyst 2350 Debug Commands debug vqpc ...
Страница 636: ...D 2 Catalyst 2350 Switch Command Reference OL 19055 01 Appendix D Acknowledgments for Open Source Software ...
Страница 652: ...Index IN 16 Catalyst 2350 Switch Command Reference OL 19055 01 ...