![Cisco Catalyst 2350 Скачать руководство пользователя страница 307](http://html.mh-extra.com/html/cisco/catalyst-2350/catalyst-2350_command-reference-manual_67583307.webp)
2-283
Catalyst 2350 Switch Command Reference
OL-19055-01
Chapter 2 Catalyst 2350 Cisco IOS Commands
show interfaces
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ----------------- ---------- --------- --------- ---------
Gi0/3 N/A ( -0.0) -- -0.0 -0.0 -0.0 -0.0
This is an example of output from the
show interfaces tengigabitethernet
interface-id
transceiver
detail
command:
Switch#
show interfaces tengigabitethernet0/1 transceiver detail
Transceiver monitoring is disabled for all interfaces.
ITU Channel not available (Wavelength not available),
Transceiver is internally calibrated.
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.
High Alarm High Warn Low Warn Low Alarm
Temperature Threshold Threshold Threshold Threshold
Port (Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
--------- ------------------ ---------- --------- --------- ---------
Te0/1 26.8 70.0 60.0 5.0 0.0
High Alarm High Warn Low Warn Low Alarm
Voltage Threshold Threshold Threshold Threshold
Port (Volts) (Volts) (Volts) (Volts) (Volts)
--------- --------------- ---------- --------- --------- ---------
Te0/1 3.15 3.63 3.63 2.97 2.97
High Alarm High Warn Low Warn Low Alarm
Current Threshold Threshold Threshold Threshold
Port (milliamperes) (mA) (mA) (mA) (mA)
--------- ----------------- ---------- --------- --------- ---------
Te0/1 5.0 16.3 15.3 3.9 3.2
Optical High Alarm High Warn Low Warn Low Alarm
Transmit Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
--------- ----------------- ---------- --------- --------- ---------
Te0/1 -1.9 1.0 0.5 -8.2 -8.5
Optical High Alarm High Warn Low Warn Low Alarm
Receive Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ----------------- ---------- --------- --------- ---------
Te0/1 -1.4 1.0 0.5 -14.1 -15.0
This is an example of output from the
show interfaces tengigabitethernet
interface-id
transceiver
properties
command:
Switch#
show interfaces tengigabitethernet0/1 transceiver properties
Transceiver monitoring is disabled for all interfaces.
ITU Channel not available (Wavelength not available),
Transceiver is internally calibrated.
Name : Te0/1
Administrative Speed: 10000
Administrative Duplex: full
Administrative Auto-MDIX: on
Administrative Power Inline: N/A
Operational Speed: 10000
Operational Duplex: full
Operational Auto-MDIX: off
Media Type: 10GBase-LR
Содержание Catalyst 2350
Страница 14: ...Contents xiv Catalyst 2350 Switch Command Reference OL 19055 01 ...
Страница 18: ...xviii Catalyst 2350 Switch Command Reference OL 19055 01 Preface ...
Страница 606: ...B 66 Catalyst 2350 Switch Command Reference OL 19055 01 Appendix B Catalyst 2350 Debug Commands debug vqpc ...
Страница 636: ...D 2 Catalyst 2350 Switch Command Reference OL 19055 01 Appendix D Acknowledgments for Open Source Software ...
Страница 652: ...Index IN 16 Catalyst 2350 Switch Command Reference OL 19055 01 ...