show vlan
Usage Guidelines
In the
show vlan mtu
command output, the MTU_Mismatch column shows whether all the ports in the
VLAN have the same MTU. When
yes
appears in this column, it means that the VLAN has ports with
different MTUs, and packets that are switched from a port with a larger MTU to a port with a smaller
MTU might be dropped. If the VLAN does not have an SVI, the hyphen (-) symbol appears in the
SVI_MTU column. If the MTU-Mismatch column displays
yes
, the names of the port with the MinMTU
and the port with the MaxMTU appear.
Expressions are case sensitive. For example, if you enter |
exclude output
, the lines that contain
output
do not appear, but the lines that contain
Output
appear.
Examples
This is an example of output from the
show vlan
command.
Table 2-22
describes the fields in the display.
Switch>
show vlan
VLAN Name Status Ports
---- -------------------------------- --------- -------------------------------
1 default active Gi0/1, Gi0/2, Gi0/3, Gi0/4
Gi0/5, Gi0/6, Gi0/7, Gi0/8
Gi0/9, Gi0/10, Gi0/11, Gi0/12
Gi0/13, Gi0/14, Gi0/15, Gi0/16
Gi0/17, Gi0/18, Gi0/19, Gi0/20
Gi0/21, Gi0/22, Gi0/23, Gi0/24
Gi0/25, Gi0/26, Gi0/27, Gi0/28
Gi0/29, Gi0/30, Gi0/31, Gi0/32
Gi0/33, Gi0/34, Gi0/35, Gi0/36
Gi0/37, Gi0/38, Gi0/39, Gi0/40
Gi0/41, Gi0/42, Gi0/43, Gi0/44
Gi0/45, Gi0/46, Gi0/47, Te0/1
Te0/2
<output truncated>
2 VLAN0002 active
3 VLAN0003 active
<output truncated>
1000 VLAN1000 active
1002 fddi-default active
1003 token-ring-default active
1004 fddinet-default active
1005 trnet-default active
VLAN Type SAID MTU Parent RingNo BridgeNo Stp BrdgMode Trans1 Trans2
---- ----- ---------- ----- ------ ------ -------- ---- -------- ------ ------
1 enet 100001 1500 - - - - - 1002 1003
2 enet 100002 1500 - - - - - 0 0
3 enet 100003 1500 - - - - - 0 0
<output truncated>
1005 trnet 101005 1500 - - - ibm - 0 0
Remote SPAN VLANs
------------------------------------------------------------------------------
Primary Secondary Type Ports
------ --------- ----------------- ------------------------------------------
Содержание Catalyst 2350
Страница 14: ...Contents xiv Catalyst 2350 Switch Command Reference OL 19055 01 ...
Страница 18: ...xviii Catalyst 2350 Switch Command Reference OL 19055 01 Preface ...
Страница 606: ...B 66 Catalyst 2350 Switch Command Reference OL 19055 01 Appendix B Catalyst 2350 Debug Commands debug vqpc ...
Страница 636: ...D 2 Catalyst 2350 Switch Command Reference OL 19055 01 Appendix D Acknowledgments for Open Source Software ...
Страница 652: ...Index IN 16 Catalyst 2350 Switch Command Reference OL 19055 01 ...