2-264
Catalyst 2350 Switch Command Reference
OL-19055-01
Chapter 2 Catalyst 2350 Cisco IOS Commands
show errdisable flap-values
show errdisable flap-values
Use the
show errdisable flap-values
user EXEC command to display conditions that cause an error to
be recognized for a cause.
show errdisable flap-values
[ | {
begin
|
exclude
|
include
}
expression
]
Syntax Description
Command Modes
User EXEC
Command History
Usage Guidelines
The
Flaps
column in the display shows how many changes to the state within the specified time interval
will cause an error to be detected and a port to be disabled. See the “Examples” section for an example
of the display.
Expressions are case sensitive. For example, if you enter
| exclude output
, the lines that contain
output
are not displayed, but the lines that contain
Output
are displayed.
Examples
This is an example of output from the
show errdisable flap-values
command, which shows that an error
will be assumed and the port shut down if three Dynamic Trunking Protocol (DTP)-state (port mode
access/trunk) or Port Aggregation Protocol (PAgP) flap changes occur during a 30-second interval, or
if 5 link-state (link up/down) changes occur during a 10-second interval:
Switch>
show errdisable flap-values
ErrDisable Reason Flaps Time (sec)
----------------- ------ ----------
pagp-flap 3 30
dtp-flap 3 30
link-flap 5 10
Related Commands
| begin
(Optional) Display begins with the line that matches the
expression
.
| exclude
(Optional) Display excludes lines that match the
expression
.
| include
(Optional) Display includes lines that match the specified
expression
.
expression
Expression in the output to use as a reference point.
Release
Modification
12.2(46)EY
This command was introduced.
Command
Description
errdisable detect cause
Enables error-disabled detection for a specific cause or all causes.
show errdisable detect
Displays error-disabled detection status.
show errdisable recovery
Displays error-disabled recovery timer information.
show interfaces
status
Displays interface status or a list of interfaces in error-disabled state.
Содержание Catalyst 2350
Страница 14: ...Contents xiv Catalyst 2350 Switch Command Reference OL 19055 01 ...
Страница 18: ...xviii Catalyst 2350 Switch Command Reference OL 19055 01 Preface ...
Страница 606: ...B 66 Catalyst 2350 Switch Command Reference OL 19055 01 Appendix B Catalyst 2350 Debug Commands debug vqpc ...
Страница 636: ...D 2 Catalyst 2350 Switch Command Reference OL 19055 01 Appendix D Acknowledgments for Open Source Software ...
Страница 652: ...Index IN 16 Catalyst 2350 Switch Command Reference OL 19055 01 ...