![Cisco Catalyst 2350 Скачать руководство пользователя страница 304](http://html.mh-extra.com/html/cisco/catalyst-2350/catalyst-2350_command-reference-manual_67583304.webp)
2-280
Catalyst 2350 Switch Command Reference
OL-19055-01
Chapter 2 Catalyst 2350 Cisco IOS Commands
show interfaces
This is an example of output from the
show interfaces stats
command for a specified VLAN interface.
Switch#
show interfaces vlan 1 stats
Switching path Pkts In Chars In Pkts Out Chars Out
Processor 1165354 136205310 570800 91731594
Route cache 0 0 0 0
Total 1165354 136205310 570800 91731594
This is an example of partial output from the
show interfaces status
command. It displays the status of
all interfaces.
Switch#
show interfaces status
Port Name Status Vlan Duplex Speed Type
Gi0/1 connected routed a-half a-100 10/100/1000BaseTX
Gi0/2 notconnect 121,40 auto auto 10/100/1000BaseTX
Gi0/3 notconnect 1 auto auto 10/100/1000BaseTX
Gi0/4 notconnect 18 auto auto Not Present
Gi0/5 connected 121 a-full a-1000 10/100/1000BaseTX
Gi0/6 connected 122,11 a-full a-1000 10/100/1000BaseTX
<output truncated>
Gi0/1 notconnect 1 auto auto 10/100/1000BaseTX
Gi0/2 notconnect 1 auto auto unsupported
<output truncated>
These are examples of output from the
show interfaces status
command for a specific interface.
Switch#
show interfaces gigabitethernet0/2 status
Port Name Status Vlan Duplex Speed Type
Gi0/2 test2 notconnect 1 auto auto 10/100/1000Ba
seTX
This is an example of output from the
show interfaces status err-disabled
command. It displays the
status of interfaces in the error-disabled state.
Switch#
show interfaces status err-disabled
Port Name Status Reason
Gi0/2 err-disabled gbic-invalid
Gi0/3 err-disabled dtp-flap
This is an example of output from the
show interfaces switchport
command for a port.
Table 2-17
describes the fields in the display.
Switch#
show interfaces gigabitethernet0/1 switchport
Name: Gi0/1
Switchport: Enabled
Administrative Mode: dynamic desirable
Operational Mode: down
Administrative Trunking Encapsulation: dot1q
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Administrative Native VLAN tagging: enabled
Voice VLAN: none
Administrative private-vlan host-association: none
Administrative private-vlan mapping: none
Administrative private-vlan trunk native VLAN: none
Administrative private-vlan trunk Native VLAN tagging: enabled
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk associations: none
Administrative private-vlan trunk mappings: none
Operational private-vlan: none
Содержание Catalyst 2350
Страница 14: ...Contents xiv Catalyst 2350 Switch Command Reference OL 19055 01 ...
Страница 18: ...xviii Catalyst 2350 Switch Command Reference OL 19055 01 Preface ...
Страница 606: ...B 66 Catalyst 2350 Switch Command Reference OL 19055 01 Appendix B Catalyst 2350 Debug Commands debug vqpc ...
Страница 636: ...D 2 Catalyst 2350 Switch Command Reference OL 19055 01 Appendix D Acknowledgments for Open Source Software ...
Страница 652: ...Index IN 16 Catalyst 2350 Switch Command Reference OL 19055 01 ...