5-35
Cisco 7600 Series Router Installation Guide
OL-4503-26
Chapter 5 Removal and Replacement Procedures
Removing and Replacing the Power Supply
Figure 5-38
Handling a DC-Input Power Supply without IPM
Figure 5-39
Handling a DC-Input Power Supply with IPM
If the power supply bay is to remain empty, install a blank power supply filler plate (Cisco part number
700-03104-01) over the opening, and secure it with the captive installation screws.
Removing a PWR-4000-DC Power Supply from a Cisco 7613 Router
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Warning
Voltage is present on the backplane when the system is operating. To reduce risk of an electric shock,
keep hands and fingers out of the power supply bays and backplane areas.
Follow these steps to remove a DC-input power supply:
Step 1
Verify that power is off to the DC circuit connected to the DC-input power supply you are removing.
191308