2-17
Cisco 7600 Series Router Installation Guide
OL-4503-26
Chapter 2 Preparing for Installation
Site Requirements
Table 2-16
lists the power and the heat numbers for SIP modules.
Table 2-17
lists the power and the heat numbers for Ethernet Services modules.
WS-SVC-NAM-1
Network Analysis Module 1
2.89
121.38
151.73
518.14
163.15
557.14
WS-SVC-NAM-2
Network Analysis Module 2
3.47
145.74
182.18
622.13
195.89
668.95
WS-SVC-PSD-1
Persistent Storage Device
module
4.00
168.0
210.0
717.15
225.81
771.13
WS-SVC-WEBVPN-K9
WebVPN Services module
2.94
123.48
154.35
527.11
165.97
566.78
WS-SVC-WISM-1-K9
Wireless Services Module
(WiSM)
6.07
254.94
318.68
1088.25
342.66
1170.19
WS-SVC-WLAN-1-K9
Wireless LAN Services module
3.10
130.20
162.75
555.79
175.0
597.63
WS-X6066-SLB-S-K9
Content Switching module with
SSL
2.15
90.30
112.88
385.47
121.37
414.48
Table 2-15
Power Requirements and Heat Dissipation—Service Modules (continued)
Model Number/
Module Type
Module
Current (A)
Module
Power
(Watts)
AC
DC
AC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
DC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
Table 2-16
Power Requirements and Heat Dissipation—SIPs
Model Number/
Module Type
Module
Current (A)
@ 42 VDC
Module
Power
(Watts)
AC
DC
AC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
DC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
7600-SIP-200
5.69
239
299
1021
322
1100
7600-SIP-400
5.95
250
312
1065
338
1154
7600-SIP-600
6.42
270
338
1153
363
1240
Table 2-17
Power Requirements and Heat Dissipation—Ethernet Services
Model Number/
Module Type
Module
Current (A)
@ 42 VDC
Module
Power
(Watts)
AC
DC
AC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
DC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
7600-ES20-10G3CXL
8.11
341
426
1454
458
1563
7600-ES20-10G3C
8.11
341
426
1454
458
1563