VCC-2CXP6M
Rev.905-0186-02
©2019 CIS Corporation. All rights reserved.
25
The registerable number of pixel defects and the correctable number of pixel defects may not be always
the same because of the following reasons.
(1)
With white defects detection, if one of the strip reed reached the maximum number, correction could
not be performed. In such case, the data up to that point are registered, error is output, and operation
ends.
(2)
If no effective pixel exists up next, down next, right next, or left next to the pixel to be corrected, this
pixel can be registered but cannot be corrected.
□
Defective pixels indication
This is to indicate the coordinate of defect registered by user.
AnalogControl
RegisteredDefectSelector
UserState/InitialState
DefectPixelNumber
1~128/1~384
DefectPixelOffsetY
(ReadOnly)
DefectPixelOffsetX
(ReadOnly)
DefectPixelType
(ReadOnly)
RegisteredDefectSelector: This is to select the type of defect.
DefectPixelNumber: This is to set the number to the registered defect.
The table number of the defect data at ex-factory and the defect registered by user
shall be specified.
DefectPixelOffsetY: This is to indicate the Y coordinate of the defect specified at DefectPixelNumber.
65535 shall be indicated for the number of the table which does not have defect
data.
DefectPixelOffsetX: This is to indicate the X coordinate of the defect specified at DefectPixelNumber.
65535 shall be indicated for the number of the table which does not have defect
data.
DefectPixelType: This is to indicate the defect type specified at DefectPixelNumber.
1:
White defect at ex-factory
2:
Black defect at ex-factory
6:
Defect registered by user
7: Defect additionally registered by user
65535: The table which does not have defect data
AnalogControl
ChannelNumber
1~4
DefectPixelChannelCount
(ReadOnly)
ChannelNumber: This is to specify the channel number of defect processing.
DefectPixelChannelCount: This is to indicate the number of defects of channel number specified at
ChannelNumber. The specified number of the defect of the channel number is the
sum total of the defects at ex-factory and the number of defects registered by user.