![CIS VCC-2CXP6M Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/cis/vcc-2cxp6m/vcc-2cxp6m_product-specification-and-operational-manual_2608737019.webp)
VCC-2CXP6M
Rev.905-0186-02
©2019 CIS Corporation. All rights reserved.
16
□
Trigger input during exposure time shall be ignored in the camera. However, a trigger shorter than 1 frame cycle
should not be used.
□
Triggers can be accepted while outputting video output images. However, please be noted that a trigger signal to
start the next video outputting should not be input before completion of outputting the prior images. (Please refer to
(A) in the drawing below).
Effective Line : 1248H
Effective Line
~
~
Exposure Out
1
2
4
8
1
TRIG IN
LVAL Out
FVAL Out
Video Out
~ ~
1
2
4
8
1
Effective Line
Trigger input ignore period
Exposure Time
Exposure Time Delay
①
Exposure Time Delay
②
(A)
TRIG IN
Exposure Out
Exposure time delay
①
Image
Header
Idle
Stream data
Stream data
Idle
Idle
Image
Header
Cxp Stream
②
5.11.
FAST Pulse Width Trigger Shutter Mode (ClockSync) CLK Sync. Trigger
(TriggerMode=On, TriggerSyncMode=ClockSync, TriggerActivation=LevelHigh)
□
This is the mode to start exposure with external input trigger signals, and set the exposure time with pulse width of
the trigger signals.
□
Trigger operation is CLK sync., and V-sync. restart system.
The delay time (Exposure Time Delay
①
) from
detecting trigger edge in the camera to actually starting exposure is
approx. 0.13µs. The delay time (Exposure Time Delay
②
) from
detecting trigger edge in the camera to end
exposure is approx. 4.997µs.
□
Pulse width
0.74μs
(Min.) ~ Approx. 2 frames
Functionally, there is no upper limitation, but noises such as dark noises shadings may be noticeable at long time
exposure.
□
There is an exposure time period for
approx. 4.997μs
at the edge right after exposure output.
SP OUT
(Exposure Out)
Actual exposure period
Approx. 4.997us