![CIS VCC-2CXP6M Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/cis/vcc-2cxp6m/vcc-2cxp6m_product-specification-and-operational-manual_2608737020.webp)
VCC-2CXP6M
Rev.905-0186-02
©2019 CIS Corporation. All rights reserved.
17
□
Trigger input during readout time shall be ignored in the camera. (Please refer to (A) in the drawing below).
Effective Line : 3000H
Effective Line
~ ~
Exposure Out
3
0
0
0
1
TRIG IN
LVAL Out
FVAL Out
Video Out
Effective Line
Trigger input ignore period
Exposure Time
Exposure Time Delay
①
Exposure Time Delay
②
(A)
TRIG IN
Exposure Out
Exposure time delay
①
②
Effective Line
~ ~
1
Next trigger rise prohibited period : 3082H
Image
Header
Idle
Stream data
Stream data
Idle
Image
Header
Cxp Stream
5.12.
Exposure Time
Acquisition Control
ExposureMode
Timed
TriggerWidth
ExposureTime
(us)
5us~Max. exposure time: LineSync
10us~200ms: ClockSync
ExposureTimeMax
(ReadOnly)
ExposureMode (Read only): This is to check if the current mode is at Timed or TriggerWidth (PWC).
ExposureTime: Exposure time (Valid when ExposureMode is at Timed)
・
Please set per 1H at H sync trigger. It shall return the value (us) rounded by 1H per Min. 1H mode.
・
It can be set per approx. 1us at CLK sync. trigger.
ExposureTimeMax: Max. exposure time
・
Please set the smaller value than ExposureTimeMax at internal sync. mode.
It shall depends on partial scan (ROI) settings, PixelFormat, and link rate.
※
The maximum of H sync. trigger mode (LineSync) shall be clipped with effective line count (Including at partial).
※