VCC-2CXP6M
Rev.905-0186-02
©2019 CIS Corporation. All rights reserved.
20
Example: 3 partial areas to be set.
Partial scan start position1
(
Region1 OffsetY
)
④
③
②
FVAL
LVAL
①
⑤
②
③
④
Video Out
Partial scan effective lines 1
④
③
②
Partial Scan Setting
Sequence of Video Output
Partial scan effective lines 1
(
Region1 Height
)
Partial scan start position2
(
Region2 OffsetY
)
Partial scan start position3
(
Region3 OffsetY
)
Partial scan effective lines 2
Partial scan effective lines 3
Partial scan effective lines 2
(
Region2 Height
)
Partial scan effective lines 3
(
Region3 Height
)
①
: V blanking line
②
: Partial area 1
③
: Partial area 2
④
: Partial area 3
⑤
: Frame total line count
When setting several partial scan areas, please set the start position and effective lines trying not to overlap the areas.
□
8Total line count per frame = V blanking lines +
Partial effective line 1 + Partial effective lines 2 +
・・・
+ Partial effective lines 8
Please note that sum total of partial effective line numbers from 1~8 (except V blanking lines) has to be less than
1248.
V blanking lines at partial mode is 64 or 68H.