VCC-2CXP6M
Rev.905-0186-02
©2019 CIS Corporation. All rights reserved.
8
4.2.
Vertical Sync. Timing
FVAL Out
Effective Line : 1248H
DVAL Out
~ ~
Effective Line
~ ~
Exposure Time
SP Out
(Exposure Out)
1
2
4
8
1
2
4
8
1
1
Video Out
Effective Line
Invalid
Line
Effective Line
Invalid
Line
V Blank
Don’t
care
Don’t
care
※The time for 1frame shall be changed depends on the link rate and video output format.
※The blanking line number for 1frame shall be changed depends on the link rate and video output format.
Effective line numbers and blanking line numbers
Video output
format
CXP-3
Mono8
1248
68
1316
6.36
8.37
Mono10
1248
68
1316
7.81
10.28
Mono12
1248
64
1312
9.21
12.08
CXP-6
Mono8
1248
68
1316
3.18
4.18
Mono10
1248
68
1316
3.91
5.15
Mono12
1248
64
1312
4.61
6.05
Sensor Operation clk
74.25 MHz
Time for 1 frame
[ms]
Link rate
Effective
line
V blank
1
frame
total
line number
Time for 1H
[us]