GE AC Instalation and operation manual V10.docx
61
/ 63
-
D:
Frequency Variation configurations. This fault makes the frequency grid to reach the
introduced frequency according to the also introduced ramp. The minimum and
maximum frequency are 10Hz and 65Hz. If the duration of the fault (introduced in H) is
not long enough, the frequency will not reach the introduced one. Press send once the
parameters are introduced.
-
E:
Flicker configurations. It will introduce an over/under voltage modulated by the
introduced frequency. The minimum and maximum values for voltage and frequency
are, respectively, 0%, 20% and 0.1Hz, 10Hz. For example, when the voltage percentage
is 20%, the voltage reaches the actual value of voltage V
RMS
± 20%. The value of
frequency represents the frequency of the modulated wave. Press send once the
parameters are introduced.
-
H:
General configurations of the fault. Enable/disable the repetition, time and set the
milliseconds between faults. Introduce the duration of the defect. Press send once the
parameters are introduced. By pressing Trigger the selected fault will start with the sent
parameters.
To stop the execution of any fault, press the STOP button in
H
zone in current tab.
It is necessary to stop the fault when another grid is required.
In order to return to grid mode, go to AC Operation tab and select it. It is not possible to go to
grid mode when any fault is activated.