![Cinergia GE10 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/cinergia/ge10/ge10_installation-and-operation-manual_2607461046.webp)
GE AC Instalation and operation manual V10.docx
46
/ 63
Operational
The main purpose of the Operational menu is allowing the user to introduce set-points as well
as manage the power supply State Machine (as long as the Local control is activated).
The user gets to read the following information as well:
Output voltage
Output current
State Machine
By means of the ENABLE and RUN buttons the user can manage the power supply State Machine.
ENABLE
: the function of this button depends on the power supply state:
-
Standby State: the ENABLE button is released. By pressing the ENABLE button the
user orders the system to move to the Ready state.
-
Ready & Run States: the ENABLE button is pressed. By pressing the ENABLE button
the user orders the system to disable the power supply.
The ENABLE button has no effect in every other state.
RUN:
the function of this button also depends on the power supply state:
-
Ready State: the RUN button is released. By pressing the RUN button the user
orders the system to move to Run State.
-
Run State: the RUN button is pressed. By pressing the RUN button the user orders
the system to return to Ready State.
The RUN button has no effect in every other State.
Commands
The user may introduce voltage, phase and frequency set-points by means of the following
buttons:
Set Voltage:
allows the user to enter
phase voltage RMS set-points.
Set Phase and Frequency:
allows the user to enter both frequency and phase set-points.