Voltage DC link
-
B:
Current trend plots:
-
Three variable per plot are allowed at the same time.
-
Due to a long refreshing time, it is not possible to detect fast current transients of
the variables.
AC Operation
This tab controls both the voltage and frequency setpoints and the harmonics.
-
A:
Harmonic control. By introducing the values for the fundamental and the harmonics,
the user can see the result in the graph before sending it. Remember that from the 1
th
until the 9
th
harmonic, the percentage can go from 0% to 100%, the 11
th
is from 0% to
50% whereas 13
th
and 15
th
can reach 10%.
-
B:
Visualization of the setpoints to send.
-
C:
Theoretic values for each phase.
-
D:
Grid setpoint control. Send the data when everything is ready.
-
E:
Select Grid Mode to introduce the values in D. Open and send the csv files. The user
can also modify the files and save them. By reseting the harmonics all harmonic
setpoints reaches to zero and generates a standard grid.
To create a .csv file with EXCEL, use only one column and separate the numbers between
comas. The decimals must be represented by points: